United States of America
OCCUPATIONAL
SAFETY AND HEALTH REVIEW COMMISSION
1120 20th Street, N.W., Ninth Floor
Washington, DC
20036-3457
Secretary
of Labor, |
|
Complainant, |
|
v. |
OSHRC Docket No. 11-1734 |
CALPINE CORPORATION, and its successors, |
|
Respondent. |
|
ON BRIEFS:
M. Patricia Smith, Solicitor;
Joseph M. Woodward, Associate Solicitor; Heather Phillips, Counsel for
Appellate Litigation; Scott Glabman, Senior Appellate Attorney; U.S. Department
of Labor, Washington, D.C.
For the
Complainant
Frank C. Botta, Esq.; Jeremy L.S.
Samek, Esq.; Willis Siegfried, Esq.; Eckert Seamans Cherin & Mellott, LLC, Pittsburgh,
PA
For the
Respondent
DECISION
Before:
MacDOUGALL, Chairman;
ATTWOOD and SULLIVAN, Commissioners.
BY THE COMMISSION:
Calpine Corporation owns
and operates a power generating plant in Bethlehem, Pennsylvania known as the
Bethlehem Energy Center (BEC). Following
an incident in which an employee fell to his death, OSHA inspected the BEC and
issued Calpine a one-item serious citation with a proposed penalty of $7,000. As amended, the citation alleges that Calpine
violated 29 C.F.R. § 1910.23(a)(7), which requires that “[e]very temporary
floor opening . . . have standard railings, or . . . be
constantly attended by someone[.]”[1]
Administrative Law Judge
Dennis L. Phillips vacated the citation, finding that no Calpine employees were
exposed to the violative condition. For
the following reasons, we reverse the judge and affirm the citation.
BACKGROUND
At the time of the incident,
Calpine had contracted with Siemens Energy, Inc. to perform a maintenance
overhaul of several turbines at the BEC, including a turbine referred to as
CT-6. During the overhaul, Siemens
disassembled and then reassembled CT-6, which contains two combustion chambers
with an upper platform surrounding each chamber that connects via a
catwalk. The platform is slightly more
than seventeen feet above the concrete floor of the building and accessible using
either of two ladders—one for the east chamber and one for the west chamber. To work on CT-6, Siemens had to remove grates
from sections of the platform, creating several openings.
On December 20, 2010,
Calpine’s operations manager, Thomas Narkin, issued a work order that
instructed the Calpine maintenance employees working the night shift to “install
[a] new spark rod . . . in CT-6 where one was ‘borrowed’ for
[another turbine] this past weekend.” The
task, which could be performed by any one of the night shift’s four maintenance
employees, required accessing the upper platform, as the spark rod needed to be
installed near the top of CT-6 in the east chamber. During the night shift that began the evening
of December 20, at approximately 4:30 a.m. on December 21, a Calpine lead maintenance
operator (LMO), Timothy Lewis, entered the building that housed CT-6 using its
southwest access door, intending to replace the spark rod.[2] After Lewis entered the building and looked
up from the ground level, he noticed the openings in the platform and decided
that the task “wasn’t safe to do.”
On the night shift that
began the evening of December 21, Narkin listed the replacement task on a work
order for the second time. He then left
the work order and replacement part in the control room, which is located on
the west side of CT-6. The work order
did not mention that the upper platform contained openings.[3] The platform opening at issue was “pretty
close to” the west chamber ladder and had neither railings nor an
attendant.
During that night shift,
sometime after 3:30 a.m. on December 22, another Calpine LMO entered the CT-6
building with work gloves on and the replacement part in his pocket, but
without the tools required for the replacement task. No one saw what occurred after he entered the
building. His co-workers found him
around 5:30 a.m. on the concrete floor near the base of the west chamber ladder. He suffered fatal head and neck injuries as a
result of a fall.[4]
DISCUSSION
To establish a violation,
“the Secretary must show by a preponderance of the evidence that: (1) the cited
standard applies; (2) there was a failure to comply with the cited standard;
(3) employees had access to the violative condition; and (4) the cited employer
either knew or could have known of the condition with the exercise of
reasonable diligence.” Astra Pharma. Prods., 9 BNA OSHC 2126,
2129 (No. 78-6247, 1981), aff’d in
relevant part, 681 F.2d 169 (1st Cir. 1982).
On review, Calpine argues
that § 1910.23(a)(7) does not apply here because “personal fall protection
was always worn by [its] employees.” By
the standard’s own terms, however, applicability is not conditioned on the
absence of personal fall protection. Rather,
the standard applies whenever there is a “temporary floor opening”; so, the
Secretary’s burden to establish applicability is met when he shows that such an
opening existed. See § 1910.23(a)(7) (“Every temporary floor opening shall have
standard railings, or shall be constantly attended by someone.”). Here, Calpine has not disputed the Secretary’s
contention that the cited platform opening fits within the standard’s definition
of floor opening or that the opening was temporary.[5]
As to noncompliance, the
use of an abatement measure that differs from that specified by a standard is
not a defense. See, e.g., S.A. Storer and Sons Co. v. Sec’y
of Labor, 360 F.3d 1363, 1372 (D.C. Cir. 2004) (finding controlled access
zone was not acceptable means of fall protection under cited fall protection
provision and that argument ignored “plain language of the applicable
regulations”). Calpine neither disputes
testimony from both COs that the cited platform opening lacked railings nor
claims that the opening was constantly attended. Therefore, we find that the Secretary has
established both applicability and noncompliance.
A. Exposure
To establish exposure,
the Secretary must show that an employee was actually exposed to the cited
condition or that access to the cited condition was reasonably
predictable. Phoenix Roofing Inc., 17 BNA OSHC 1076, 1079 (No. 90-2148, 1995), aff’d, 79 F.3d 1146 (5th Cir. 1996)
(unpublished). As to actual exposure,
the judge found that there was insufficient evidence that the decedent fell
through the cited opening. On review,
the Secretary makes no claim that the decedent or any other Calpine employee was
actually exposed to the hazard posed by the unguarded opening;[6] so we examine only whether
exposure to the violative condition was reasonably predictable.[7]
Reasonably
predictable exposure is established by proving that “either by operational necessity
or otherwise (including inadvertence) . . . employees have
been, are, or will be in the zone of danger.”
Nuprecon LP, 23 BNA OSHC 1817,
1819 (No. 08-1307, 2012) (citations omitted).
Employees may come within the zone of danger “while in the course of
assigned working duties, personal comfort activities while on the job or their
normal means of ingress-egress to their assigned workplaces.” Gilles
& Cotting, Inc., 3 BNA OSHC 2002, 2003 (No. 504, 1976); Donovan v. Adams Steel Erection, Inc.,
766 F.2d 804, 812 (3d Cir. 1985) (“ ‘access,’ not exposure to danger is the
proper test”). The Secretary need not
show it was certain that employees would be in the zone of danger, but he must
show that exposure was more than theoretically possible. Fabricated
Metal Prods., Inc. 18 BNA OSHC 1072, 1074 (No. 93-1853, 1997); Phoenix Roofing, 17 BNA OSHC at 1079; Kaspar Wire Works, Inc., 18 BNA OSHC
2178, 2195 (No. 90-2775, 2000) (finding that it was “ ‘reasonably predictable’
that an employee would come into contact with the unguarded belt and pulley
either while attempting to reposition the fan, or inadvertently while passing
nearby”), aff’d, 268 F.3d 1123 (D.C.
Cir. 2001).
To make this showing, the
Secretary argues that it was reasonably predictable Calpine employees would be
exposed to the platform opening at issue based on Narkin’s continuing work
order to install the spark rod near the top of CT-6. We agree.
It is undisputed that this assigned task required going on the upper
platform containing the cited opening. The platform was not complete on December 20,
when Narkin initially assigned the task, or on December 21, when he again
assigned the task.
In addition, as the
Secretary argues, there was an established “nexus between the unguarded platform
opening and the likely movements of employees assigned the task of replacing
the spark rod.” Calpine does not dispute
the Secretary’s claim that the cited opening was located “within a few feet of”
and “closely adjacent” to the west chamber ladder.[8] Two photographs in the record, along with
testimony from one of the COs, confirm that the opening was immediately
adjacent to this ladder, which had a hinged gate that allowed entrance onto the
platform. The control room, where the
work order and replacement spark rod were located, was also on the west side of
CT-6.
Although the work order
did not specify that the spark rod needed to be installed in the east chamber,
the record shows that use of the west chamber ladder was part of a reasonably
foreseeable route to where the task needed to be performed.[9] Because a platform surrounded each chamber
and they were connected via a catwalk, the east chamber was accessible via the
west chamber ladder. Three employees
testified that, given that the spark rod and work order had been placed in the
control room to the west of CT-6, the most likely route an employee performing
the task would take after retrieving the replacement part would be to enter the
building through the southwest access door closest to the west chamber ladder,
just as Lewis had done. Indeed, Lewis
explained that this was the “easiest” door to use because it provided ground-level
access and avoided the need to use a vertical ladder while carrying tools or
“hav[ing] to circle around and go into the . . . east side of the building” and
“go down some stairs.” As Lutz described
it, this route was the “path of least resistance.”
Given that the west
chamber ladder was closest to the southwest access door into the CT-6 building,
we find that it was likely an employee performing the replacement task would
use that ladder to reach the platform around the west chamber and use the
catwalk to cross over to the east chamber platform. We also find that because the west chamber
ladder was immediately adjacent to the cited platform opening, it was
reasonably predictable that any employee carrying out the assigned task would
enter the zone of danger posed by the unguarded opening. Nuprecon,
23 BNA OSHC at 1818-19 (finding exposure where it was reasonably predictable
employee would come within six feet of edge); Phoenix Roofing, 17 BNA OSHC at
1079
(“about 12 feet” from unguarded skylights); Dic-Underhill, 8 BNA OSHC 2223,
2229-30 (No. 10798, 1980) (twenty-five or more feet from an
unguarded edge, working towards that edge); Cornell & Co., 5 BNA OSHC 1736,
1738
(No. 8721, 1977) (ten feet from an elevator shaft).[10]
In sum, we find that Calpine
assigned its employees to complete a task that would bring them into the “zone
of danger” posed by the unguarded platform opening. Accordingly, we conclude the judge erred in determining
that the Secretary failed to establish exposure as the record shows it was
reasonably predictable that Calpine employees would have access to the hazard.
B. Knowledge
To
establish knowledge, the Secretary must show that the employer knew or with the
exercise of reasonable diligence could have known of a hazardous
condition. Kerns Bros. Tree Serv., 18 BNA
OSHC 2064, 2067 (No. 96-1719, 2000). A supervisor’s knowledge of the violative
condition is imputable to the employer. Tampa Shipyards, Inc., 15 BNA OSHC 1533, 1539
(No. 86-360 & 86-469, 1992) (consolidated).
Here,
the Secretary sought to establish both actual and constructive knowledge of the
unguarded platform opening. As to actual
knowledge, the Secretary claims that five Calpine supervisors knew the platform
opening was unguarded on December 21, the day before the accident. The judge agreed, finding that all
five supervisors had actual knowledge of the violative condition and that their
knowledge was imputable to Calpine.
We
agree with the judge. Five Calpine
supervisors knew of the opening on December 21—Roy Killgore, Raymond Rice,
Lewis, Lutz, and Narkin.[11] Killgore and Rice oversaw Siemens’ work during
the overhaul and were in the CT-6 building on a daily basis. They both reviewed
a report from Siemens on December 21 that indicated that Siemens had not
finished replacing the platform grates as of 5:00 p.m. that day. After Lewis saw the unguarded platform opening
when he entered the CT-6 building on the morning of December 21 to install the
spark rod, he communicated his observation to Lutz, who acknowledged in his testimony
knowing about the opening.
In addition, Lewis testified that he informed Narkin about the unguarded opening and Lutz’s testimony corroborates this: “I think [Narkin] was there when [Lewis] told me, because I kind of remember having a long conversation—a longer conversation than just a two second blurb about it.” Narkin, however, testified that he was not told about the opening. The judge credited Lewis and Lutz on this issue—specifically, he found that Narkin’s denial was a “convenient explanation for his inaction in not removing the spark rod replacement task from the night order or warning the deceased” of the opening, citing Narkin’s “defensive and unpersuasive” demeanor in testifying about this issue. We defer to the judge’s demeanor-based credibility finding and conclude that Narkin was also aware of the opening. See E.R. Zeiler Excavating Inc., 24 BNA OSHC 2050, 2057 (No. 10-0610, 2014) (appropriate for Commission to defer to judge’s demeanor-based credibility finding).
Calpine
does not dispute that it had actual knowledge on December 21, but it argues
that its supervisors lacked knowledge of the violative condition during what it
asserts is the two-hour time period relevant to the citation—between
approximately 3:30 a.m. and 5:30 a.m. on December 22. According to Calpine, (1) the supervisors who
knew of the condition on December 21 were no longer present at the BEC on
December 22; (2) conditions in the CT-6 building were constantly changing; (3)
it was entitled to rely on Siemens’ representation that it expected to reinstall
the grates to cover the platform openings during its own night shift, which ran
from 5:00 p.m. to 3:30 a.m.; and (4) it could not have determined the condition
of the platform until after Siemens’ night shift concluded because “[t]here
were no non-Siemens’ employees present between the time they ended their shift
and the time that [the decedent] entered the CT-6 building shortly thereafter.”
Contrary to Calpine’s
claim, the parties tried the case on the conditions that existed during the
Calpine night shift that began on December 21 and continued through the morning
of December 22. This is consistent with
the citation, which asserts that the violative condition existed “on or about
December 22, 2010.” Moreover, even if the period of the alleged violation was
limited to the two‑hour period as Calpine alleges, the Secretary has
nonetheless established the company’s actual knowledge of the violation. Calpine’s five supervisors knew of the
opening on December 21, and their absence in the early morning hours of
December 22, when the cited opening still existed, does not magically erase that
knowledge. See Caterpillar, Inc., 17
BNA OSHC 1731, 1732 (No. 93-373, 1996) (termination of a supervisory employee’s
employment prior to the time of the cited condition did not vitiate the
departed supervisor’s knowledge of a previous occurrence of the same condition)
(citing cases and Restatement (Second) of Agency), aff’d, 122 F.3d 437 (7th Cir. 1997).
Calpine’s
other arguments—that it lacked knowledge because conditions were changing, that
Siemens had represented that it expected to reinstall the missing grates, and
that there were no “non-Siemens’ employees” (i.e., supervisors under Calpine’s
control) in the CT-6 building during the two-hour window—are misplaced. Each of these assertions address whether
Calpine, “with the exercise of reasonable diligence, could have known of the
presence of the violative condition”—in other words, whether in light of these
alleged facts it was unreasonable to expect Calpine to have learned of the
opening. Pride Oil Well Serv., 15 BNA OSHC 1809, 1814 (No. 87-692, 1992); see also Astra Pharm. Prods., Inc., 9 BNA OSHC at 2129. Defending against a finding of actual
knowledge by making arguments relevant to constructive knowledge is
inconsistent with Commission precedent: the Secretary meets his knowledge
burden when he shows actual or
constructive knowledge—he need not establish both. See,
e.g., Tampa Shipyards, Inc., 15
BNA OSHC at 1537-39 (Secretary
established knowledge by showing actual knowledge of supervisors). Therefore, we find that Calpine had actual
knowledge of the unguarded platform opening on December 21.
Calpine’s arguments are
not even meritorious when construed as a challenge to constructive knowledge. Regardless of whether conditions in the BEC
were “constantly changing,” Calpine had an obligation to “inspect the [work]
area to determine what hazards exist or
may arise during the work before permitting employees to work in an area,
and the employer must then give specific and appropriate instructions to
prevent exposure to unsafe conditions.” Automatic Sprinkler Corp. of Am., 8 BNA
OSHC 1384, 1387 (No. 76-5089, 1980) (emphasis added). See
also Pride Oil Well Serv., 15 BNA OSHC at 1814 (employer required to
“inspect the work area, to anticipate hazards to which employees may be
exposed, and to take measures to prevent the occurrence”) (internal citations
omitted). Despite knowing of the unguarded
opening on December 21, none of the Calpine supervisors handed off that
information, such as through written instructions in the work orders. See
Wiley Organics, Inc. d/b/a Organic Tech.,
17 BNA OSHC 1586, 1597 (No. 91-3275, 1996), aff’d,
124 F.3d 201 (6th Cir. 1997) (“An employer has a general obligation to inform
itself of the hazards present
at the worksite and cannot claim lack of knowledge resulting from its own
failure to make use of the sources of information readily available to it.”)
(citations omitted).
As to Siemens’
representation that it expected to reinstall the missing platform grates during
its day shift on December 21, the record shows
that this work was in fact not completed during that shift and was instead
carried over to the next Siemens shift, as reflected on the turnover report. Rice explained that Siemens’ turnover reports
were “general reports, I mean we throw a bunch of stuff out there and you get
what you can. And then you roll it over
to the next shift.” As such, Calpine
knew that on prior occasions, not all planned work was completed during a
designated Siemens shift. In addition,
Rice and Killgore testified that there was a significant amount of work Siemens
needed to do during the overhaul, noting that “[i]t’s pretty hectic” and
various things, including an approaching storm on December 21, could affect the
progress of Siemens’ work schedule. Indeed,
when Rice left the building around 2:00 a.m. on December 22, it was readily
apparent that not all of the platform grates had been put back. As the Siemens crew was cleaning up rather
than continuing to work at that point, he would have had no reason to think
that they would complete that work before the end of their shift.
For all of these reasons,
we find that the Secretary established that Calpine had both actual and constructive
knowledge of the violative condition.
C. Unpreventable Employee Misconduct (UEM)
Defense
To
establish that a violation was the result of UEM, an employer is required to show
that it: “(1) established work rules designed to prevent the violative
conditions from occurring; (2) adequately communicated those rules to its
employees; (3) took steps to discover violations of those rules; and (4)
effectively enforced the rules when violations were discovered.” Manganas Painting Co., 21 BNA OSHC 1964, 1997 (No.
94-0588, 2007). Calpine’s allegation of
this defense is conditional—the company claims that if the decedent had gone on the CT-6 platform without using
personal fall protection (a point Calpine does not concede), such action would have constituted UEM.[12]
It should be obvious that
misconduct is a prerequisite element of the UEM defense. Indeed, the defense is predicated on the notion
that an employer should not be held responsible when the cited violative
condition was caused by an employee’s misconduct if that misconduct was not
reasonably foreseeable:
An isolated brief violation of a standard by an employee
which is unknown to the employer and is contrary to both the employer’s
instructions and a company work rule which the employer has uniformly enforced
does not necessarily constitute a violation of section 5 (a)(2) of the Act by
the employer.
Standard
Glass Co., Inc., 1 BNA OSHC 1045, 1046 (No. 259, 1972)
(emphasis added). Here, the violative
condition was the absence of either railings or an attendant at a temporary floor
opening on the platform. 29 C.F.R.
§ 1910.23(a)(7). Calpine does not
assert that its failure to install railings or assign an attendant was the
result of misconduct. In addition, personal
fall protection was not a compliance option; so Calpine’s rule requiring
employees to use personal fall protection at heights greater than four feet “is
not equivalent to the cited standard” and thus fails to satisfy the first prong
of the UEM defense. Daniel Int’l Corp., 9 BNA OSHC 2027, 2031 (No. 76-181, 1981)
(rejecting UEM defense based on employees’ failure to tie-off where
construction fall protection standard required openings to be protected by
guardrails or covers, stating that the employer’s tie-off rule “is not
equivalent to the cited standard”); see also
Boh Bros. Constr. Co., LLC, 24 BNA OSHC 1067, 1075 (No.
09-1072, 2013) (employer’s monitoring and enforcement of work rule that did not
meet cited provision’s requirements could not be used to establish UEM defense). In short, Calpine has not even alleged
conduct that would be relevant to the defense.
Even
if the failure to use personal fall protection could constitute misconduct and
Calpine had shown that the decedent had gone on the platform without using it,
the defense would still fail because Calpine has not shown misconduct by the other employees on the crew, any one of
whom was expected to complete the task and for whom exposure to the violative
condition has been established—a predicate evidentiary burden here that rests
with Calpine, since UEM is an affirmative defense. Daniel
Int’l Corp., 9 BNA OSHC at 2031. In
fact, Calpine has not even shown that the decedent went on the platform. Therefore, we reject Calpine’s UEM defense.[13]
D. Multi-Employer Worksite (MEW) Defense
To establish the MEW defense, an employer must show that it neither created nor controlled a hazardous condition to which its own employees were exposed and that it took reasonable alternative steps to protect its employees from the hazard. Rockwell Int’l Corp., 17 BNA OSHC 1801, 1808 (No. 93-45, 1996); Atl. Battery Co., 16 BNA OSHC 2131, 2166 (No. 90-1747, 1994) (multi-employer worksite defense failed when employer had control over the cited condition); Grossman Steel & Aluminum Corp., 4 BNA OSHC 1185, 1190 (No. 12775, 1976) (employer bears the burden of establishing multi-employer worksite defense).
Calpine claims that
Siemens had primary operational control over CT-6, including the platform
openings that Siemens created during the overhaul. As the judge found, however, Calpine retained
ownership and control of the entire BEC and never ceded any portion of that
control to Siemens. Calpine supervised
Siemens’ overhaul work and regularly had its own supervisor in the CT-6
building to oversee their work. In
addition, Calpine performed contractor safety audits during which it pointed
out safety issues for Siemens to correct and stopped work when Siemens
employees were found to be working in an unsafe manner. There is also no evidence that Calpine either
lacked the authority or ability to comply with the standard or to order Siemens
to comply. See Union Boiler Co., 11 BNA OSHC 1241, 1246 (No. 79-232, 1983) (MEW
defense requires showing that the employer did not possess the expertise,
personnel, or means to correct the hazard).
Therefore, Calpine has not shown it lacked “operational control” while
Siemens performed the overhaul work. Cf. Otis Elevator Co., 4 BNA OSHC 1219,
1223 (No. 8468, 1976) (finding that cited employer’s joint control of the
location of the hazard was sufficient to affirm the citation). Accordingly, Calpine was a controlling
employer whose own employees were exposed to the cited condition, which makes
it fully responsible for complying with the cited standard as an exposing
employer. See, e.g. McDevitt Street Bovis, Inc., 19 BNA OSHC 1108, 1109 (No.
97-1918, 2000) (recognizing that a controlling employer’s duties include protecting
its own employees). We therefore find
that Calpine has not established the MEW defense.
Accordingly,
we affirm the citation as serious and assess the $7,000 proposed penalty.[14]
SO ORDERED.
/s/
Heather
L. MacDougall
/s/
Cynthia
L. Attwood
Commissioner
/s/ James
J. Sullivan, Jr.
Dated: April
6, 2018 Commissioner
United States of America
OCCUPATIONAL SAFETY AND HEALTH REVIEW COMMISSION
1120 20th Street, N.W., Ninth Floor
Washington, DC 20036-3457
|
|
Complainant, |
|
v. |
OSHRC Docket No. 11-1734 |
CALPINE CORPORATION, and
its successors, |
|
Respondent. |
|
APPEARANCES:
Jessica R. Brown,
Esquire, U.S. Department of Labor, Office of the Solicitor, Region III, Philadelphia,
Pennsylvania
For
the Secretary
James G.
Seaman, Esquire, Eckert Seaman Cherin & Mellott, LLC, Pittsburg,
Pennsylvania
Frank C.
Botta, Esquire, Eckert Seaman Cherin & Mellott, LLC, Pittsburg,
Pennsylvania
Jeremy L.
Samek, Esquire, Eckert Seaman Cherin & Mellott, LLC, Pittsburg,
Pennsylvania
Willis A.
Siegfried, Esquire, Eckert Seaman Cherin & Mellott, LLC, Pittsburg,
Pennsylvania
Christopher
Jones, Esquire, Calpine Corporation, Houston, Texas
For the Respondent
BEFORE: Dennis L.
Phillips
Administrative Law Judge
DECISION AND ORDER
This proceeding is before the
Occupational Health and Safety Review Commission (“the Commission” or “OSHRC”)
pursuant to § 10(c) of the Occupational Safety and Health Act of 1970, 29
U.S.C. § 659(c) (“the Act”). On Wednesday,
December 22, 2010, upon being notified
of an accident, the Occupational
Safety and Health Administration (“OSHA”) initiated an inspection of Calpine Corporation’s
(“Respondent” or “Calpine”) Bethlehem Energy Center (“BEC”) facility in Bethlehem,
Pennsylvania. (SF-5).
In June 2011, OSHA issued a “serious”
citation, alleging a violation of 29 C.F.R. § 1910.23(a)(8), unguarded floor
hole, and proposing a penalty of $7,000.00.[15] Calpine filed a timely notice of contest,
bringing this matter before the Commission.
In her complaint, the Secretary of Labor amended the citation to allege
a violation of 29 C.F.R. § 1910.23(a)(7), unguarded temporary floor opening. In its answer, Calpine set out 19 affirmative
defenses.[16] An eight-day hearing was held in Philadelphia,
Pennsylvania in May and June, 2012. The
parties submitted a joint pre-hearing statement, post-hearing briefs, and reply
briefs. (SF-2 through 4, 15).
Jurisdiction
Based upon the record, the Court finds
that Calpine, at all relevant times, was engaged in a business affecting
commerce and was an employer within the meaning of §§ 3(3) and 3(5) of the Act,
29 U.S.C. §§ 652(3) and (5). See pleadings.
The Court concludes that the Commission
has jurisdiction over the parties and subject matter in this case. (SF-1).
Stipulated Facts
The parties stipulated the following
facts in their joint pre-hearing statement.[17]
1. Respondent is an employer engaged
in a business affecting commerce within the meaning of 29 U.S.C. § 652(5), and
Respondent utilizes tools, equipment, machinery, materials, goods and supplies
which have originated in whole or in part from locations outside the state of
Pennsylvania.
2. Calpine timely filed a Notice of
Contest to the Citation.
3. On September 16, 2011, the
Secretary of Labor (“Secretary” or the “DOL”) filed a Complaint with the
Occupational Safety and Health Review Commission (“OSHRC”). In her Complaint, the Secretary amended the
Citation to read as follows, replacing the original language.
Citation 1 Item 1a Type of Violation: Serious
29 CFR [§] 1910.23(a)(7): Temporary floor
opening(s) were not guarded by standard railings or constantly attended by
someone:
(a) CT6, adjacent to the ladder access way
– On or about December 22, 2010, a temporary floor opening in the steel grated
platform, which surrounded the turbine chamber was not guarded by standard
railings or constantly attended to prevent employees from falling a distance of
no less than 16 feet through the unguarded opening.
4. Calpine filed a timely Answer to the DOL
Complaint, denying the material allegations thereof and asserting various
affirmative defenses.
5. Bethlehem Energy Center is located at 2254 Applebutter
Road, Bethlehem, Pennsylvania 18015.
6. Joseph Miller is an employee of Calpine
Corporation.
7. Joseph Miller was the Plant Manager of
Bethlehem Energy Center at the time of the accident.
8. Thomas Narkin is an employee of Calpine
Corporation.
9. Thomas Narkin was the Operations Manager of
Bethlehem Energy Center at the time of the accident.
10. During the week of December 20, 2010, Siemens
Energy (“Siemens”) was in the process of re-assembling the CT-6 turbine. As part of that process, Siemens scheduled its
12/21/10 Day Shift (i.e., 7:00 a.m.
to 5:00 p.m.) crew to re-assemble the platforms and catwalks, which surround
and connect CT-6 combustor silos BK-1 and BK-2.
The Day Shift crew did not complete that task, however.
11. Completion of the CT-6 platforms/catwalks
configuration, which includes the BK-2 Platform, was left for Siemens’ 12/21/10
Night Shift crew (i.e., 5:00 p.m. to 3:30 a.m.). Siemens’ 12/21/10 Night Shift crew did not
complete said platforms/catwalks configuration.
12. When Siemens’ 12/21/10 Night Shift crew left
the BEC at 3:30 a.m. on December 22, 2010, the BK-2 Platform was not completely
re-assembled.
13. Using a laser measuring device, the coroner
determined the BK-2 platform to be 17’ 1 31/32” above ground level.
14. Photographs of the BK-2 Platform, which were
taken by both OSHA and the Police, as well as OSHA’s own admission reflect that
“the tarps were still on the BEC Unit 6 turbines at the time of the
Incident.” (DOL-000632.)
15. Respondent has the burden of establishing the
affirmative defense of unpreventable employee misconduct on the part of its
employee [the decedent].[18]
Relevant Testimony
The
BEC facility is a power-generating facility spread over 52 acres with two river
water cooling towers, two steam turbine buildings, six combustion turbine
buildings, two heat recovery steam generator buildings, two gas pressure
buildings and a chemical addition building.
An administrative office, maintenance shop and main control room are
also at the BEC facility. Several
combustion turbines are located at six combustion turbine buildings. The accident prompting the inspection took
place in the combustion turbine building referred to as CT-6.[19] CT-6’s gas combustion turbine is a Siemens model
V84.2. (Tr. 444-45, 505, 948, 1360, 1384,
1422-23, 1439; RX-P, at p. 5, RX-MM-I).
The BEC facility was commissioned in
2002 and transferred to Calpine’s ownership in July 2010.[20] Joseph M. Miller III became the plant manager
at the BEC facility at that time.[21] Previously, Mr. Miller was the operations and
maintenance manager at a power plant in Wilmington, Delaware for about ten
years. (Tr. 1447, 1531-32; SF 6-7, 9).
Thomas
Narkin became the Operations Manager at the BEC facility in the spring of
2009. Mr. Narkin is responsible for
managing 17 operator maintenance technicians (“OMT”), four of which are lead
maintenance operators (“LMO”).[22] He graduated from Widener University and is
an electrical engineer. LMOs operate the
BEC facility, perform maintenance work, and help coordinate what gets done each
day. In December 2010, there were four
LMOs – Raymond Lutz, William Varga, Timothy Lewis, and the decedent.[23] (Tr. 439-40, 566-67, 606, 693-95, 988-89, 992,
1435-39, 1440; SF-8 through 9).
Calpine’s
operations staff worked in 12-hour shifts starting at 6:00 a.m. and 6:00 p.m. There were four operations staff members per
shift – three OMTs and one LMO.[24] Each LMO is responsible for the oversight of three
OMTs per shift. An OMT’s routine duties
include checking meter readings, plant chemistry, starting and stopping
equipment, observing equipment for potential problems, controlling
megawatt-levels, maintaining offsite auxiliary equipment, and general light
maintenance. Mr. Narkin stated that OMTs
are required to inform him of any unusual condition and either stop or not
start a job when they discover a safety issue.
He testified that an LMO is responsible for his own safety, the safety
of his crew, and delegating work tasks.[25] In addition, Mr. Narkin testified that one of
the LMO’s duties including attempting to resolve safety issues, and, if unable
to do so, to then contacting the on-call supervisor. [26] (Tr. 441-42, 694, 999, 1440-47; RX-X).
The Overhaul Project
In
2010, Calpine hired an outside contractor, Siemens, to perform a maintenance
overhaul of several turbines at the BEC facility. The overhaul effort included CT-6’s gas turbine’s
disassembly and reassembly.[27] At the time of the accident, Siemens was overhauling
the CT-6 turbine and it was in outage mode (not generating energy).[28] Mr. Narkin testified that during the overhaul
Siemens directed and controlled the end of CT-6 where the turbine was located.[29] Calpine employees were occasionally borrowed
to perform tasks at Siemens’ request.
(Tr. 453, 1365, 1384, 1474-80; RX-N, RX-P, at p. 40).
Raymond
Rice and Roy Killgore were turbine engineers for Turbine Maintenance Group
(“TMG”) and worked at the BEC facility during the overhaul project.[30] TMG, a division of Calpine Operating Services
Company, Inc. (“COSCI”), is based in Pasadena, Texas. TMG oversees the Master Agreement between
Siemens and Calpine and the Operating Plant Service Agreement (“OPSA”) between
COSCI and Siemens and provides technical oversight during overhauls at
approximately 97 Calpine-owned facilities in the United States. Mr. Narkin explained that the TMG engineers served
as an intermediary between Siemens and BEC’s plant management.[31] Mr. Miller testified that “the TMG group is
kind of like an internal subcontractor, ….”
He also stated that Mr. Killgore was “kind of the company administrator”
for the OPSA between Siemens and Calpine.
(Tr. 932-33, 942-45, 1068-70, 1080. 1333-34, 1476, 1569-70; RX-N, RX-P).
Messrs.
Killgore and Rice were on site to ensure that Siemens followed the technical specifications
for the overhaul project. They worked
hours to correspond with the Siemens crews’ shifts. Mr. Rice had oversight for the night shift; Mr.
Killgore was on the day shift. Mr.
Killgore estimated that during the overhaul he spent 60% to 90% of his time in
the area where Siemens was working. (Tr.
937-38, 1375-78, 1385; JX-VII at p. 5).
Mr.
Killgore testified that Siemens personnel conducted a daily turnover meeting to
“basically recap the day’s work for their night shift people coming in, and the
night shift was gathering that information so they could go to work.” Messrs. Killgore and Rice attended the
meeting to review the technical issues and determine whether BEC staff would be
needed to perform a task. Siemens also
prepared a Shift Turnover Report that showed work that had been accomplished
and identified work to be scheduled. Mr.
Rice testified that a completed copy of the Siemens Shift Turnover Report for
the December 21, 2010 dayshift was not sent to Calpine’s Control Room on the
evening of December 21, 2010.[32] That report indicated that the platforms and
catwalks had been hot bolted by about 5:00 p.m., December 21, 2010, but further
work needed to be scheduled to torque the platforms and double nut them as
necessary for looseness.[33] The Shift Turnover Report completed for the
5:00 p.m. through 3:30 a.m., December 21-22, 2010 night shift continued to
indicate that work needed to be scheduled to finish torqueing the platform
sections.[34] (Tr. 366-67, 424-25, 964-77, 981-82, 1288-90,
1376-79; JX-III, at p. 2, JX-VII, at p. 10, JX-XV, GX-7).
Mr.
Killgore prepared the “Calpine TMG Daily Shift Turnover Report” each morning, which
was then sent to Mr. Rice, Mr. Miller, TMG’s management, and Calpine’s regional
vice president, Bill Ferguson. [35] The report was also a summary of what Siemens
had accomplished in the prior 24 hours.[36] Mr. Killgore received the information for
this report from the Siemens daily turnover meeting he attended and a report that
Siemens sent to him between 6:00 a.m. and 8:30 a.m. each morning which listed
the work done overnight.[37] Mr. Killgore also testified that one of his
duties was to show Siemens’ employees a safety video as part of Calpine’s safety
training of Siemens’ personnel working at BEC.
(Tr. 1020, 1076-80, 1379-82, 1424-25, 1572; GX-8, GX-9, GX-13).
Siemens
controlled the priority of the work tasks related to the overhaul. Mr.
Killgore explained that the project’s status could change quickly because
Siemens had to deal with various factors, such as the weather, while trying to
meet its schedule. For example, Mr. Rice
testified that on December 21, there was a blizzard predicted so the early part
of that night’s shift was dedicated to getting a roof panel replaced. (Tr. 900-01, 961-62, 965, 1377, 1395, 1538-39;
RX-D). Mr. Rice testified that work by a
BEC employee in the overhaul work area was limited to those tasks necessary to
assist Siemens during the outage.[38] Siemens was not allowed to perform certain
tasks at the BEC facility. For example,
if Siemens needed a piece of instrumentation moved, it would request a BEC
technician to perform the work. (Tr.
1385-86). Messrs. Lewis, Lutz, Miller and Rice
confirmed that BEC staff was only in CT-6 during the overhaul to perform
certain limited tasks.[39] Mr. Killgore’s duties included coordinating tasks,
such as to remove wiring, electrical hookups, or conduct crane operations, that
Calpine BEC employees needed to perform in the southern half of CT-6 while
Siemens was engaged in its overhaul work in that area. (Tr. 454, 529, 644-45, 959-60, 1018-19, 1385-87).
Mr.
Killgore testified that Siemens could begin to reassemble the catwalk platforms
after completing the re-installation of the rotor, compressor blade and turbine
vane carriers, center and exhaust cases, and blow off line in CT-6’s
turbine. (Tr. 1393). Siemens installed the center case during the
December 20, 2010 night shift. (GX-6, at
p. 2). Siemens hot-bolted the platforms
and catwalks around the two combustion chambers during the December 21, 2010
day shift. Siemens’ December 21, 2010
night shift did not perform any work on the upper platforms in CT-6. Siemens’ December 21, 2010 night shift Shift
Turnover Report indicated that “Finish torquing platform sections” was
scheduled work that needed to be done.
(Tr. 1394-96; GX-7).
During
the overhaul project, Thomas McClelland[40] performed
tasks in CT-6 in December, 2010. Mr.
McClelland testified that in order to remove a pipe in CT-6, “I went into the
enclosure to assess the job. Looked up
to see where I had to work and made sure it was safe or if it wasn't, which at
that time it was not. So I went back and
got my fall protection, came back, did the job.” He testified that he used fall protection
because the catwalk platform was not complete.[41] A few days before the accident, Mr. McClelland
went back to replace the same pipe in CT-6.
Again, he “walked over to the unit, looked around where I needed to
work, made sure it was safe, and if not went back and got my safety equipment
and then went and did my job.” He
testified that he assessed the situation before he did any work because that
was a “personal way I work”, safety training he had, and Calpine’s safety
policies. (Tr. 1798-1804).
Mr.
Narkin prepared a night order for each upcoming BEC night shift. The night order was a list of tasks to be
done, generally listed in the order of priority. Mr. Narkin testified that he did not expect
all the listed tasks to be done on a particular night. If a task was critical he would note it as such
with a desired completion date. Further,
Mr. Narkin testified that he put some tasks on the list in advance of the
needed completion date as a way to encourage communication between him and the
operations staff about a planned future task.
(Tr. 447, 1462-71).
Mr.
Lutz described a night order as the way management relayed tasks to the night
shift. Night orders were placed on the
Control Room’s counter by the operations manager, Mr. Narkin. These tasks were in addition to the routine
duties of the operations staff. The
night order was primarily for the LMO’s use, but it was available to any
employee. Mr. Lutz explained that the
expectation was to complete as many tasks as possible from the night order. Mr. Lutz further explained that there was some
pressure to get priority tasks that were critical done for the next day’s
shift. He also testified that in
December 2010 it was common for LMOs to enter into CT-6 to assist Siemens by turning
on or off one of Calpine’s pumps, as well as to perform minor “quickie” jobs
that did not require much time to complete.[42] One such job included performing plastic
sheeting repair work to protect electrical components when the roof was
removed. (Tr. 447-51, 455-56, 530-31,
644, 991, 1478; JX-XIII, GX-10).
Mr.
Narkin testified that employees have discretion as to which tasks will be done
each night and that employees can skip tasks, “which happens a lot.” Mr. Narkin testified that besides being able
to skip items on the night orders when there was not time to complete the task
by the end of a shift, employees were expected to skip a task when it could not
be performed safely. Mr. Lewis confirmed that safety issues,
potential hazards, physical capabilities of the person performing the task,
weather conditions, and operational conditions were all reasons to skip over a
task on a night order.[43] Mr. Varga testified that he did not believe
anyone had ever been disciplined for not completing a task on a night order. He also agreed that it was appropriate to
assess environmental conditions before performing any task. (Tr. 649-50, 741-42, 1462-64).
Mr.
Lutz testified that he told Mr. Narkin that the men were feeling stressed about
finishing all the tasks on the list each night.
Mr. Narkin then sent out three emails clarifying the priority of tasks
on a night order. Mr. Narkin sent these
emails on August 20, November 18 and November 24, 2010. The emails were written to remind the
employees that the jobs on the night orders were to be completed only if time
and conditions allowed, that the listed tasks were secondary to their routine
duties and safety training, and that Mr. Narkin did not expect them to complete
all the tasks listed during that shift.
The decedent was one of the recipients of these emails. (Tr. 539-40, 548-50, 651-52, 1465-71; RX-DD).
On
the December 20 night order, Mr. Narkin included an assignment to re-install a
spark rod[44] where
one had been removed a few days before from CT-6’s east combustion chamber burner
by the deceased.[45] Mr. Narkin testified that he knew that
installing the spark rod in CT-6 required the use of the upper platform that
surrounded the combustion chambers. He
also testified that he did not take any steps at that time to determine the
condition of CT-6’s catwalk platform. (Tr. 1003-4; GX-5).
Mr.
Lewis attempted to complete the spark plug replacement assignment at
approximately 4:30 a.m. on December 21. He
did not know into which of the two combustion chambers the spark plug was to be
installed.[46] (Tr. 460-63, 566, 569-74, 998, 1003-06,
1483-85; GX-5, RX-MM). Mr. Lewis further
testified that he entered CT-6’s southern door after exiting the Heat Recovery
Steam Generator (“HRSG”) building. The
farthest point he reached was directly south of the west combustion
chamber. From there, he could see that “[t]he
tops of the combustion chambers were covered with tarps over the top of the
burners where this spark rod assembly would go . . . . in addition to the tarps
covering the combustors there was decking missing from these catwalks.”[47] He also testified that he observed the opening
in the platform from floor level and that it was so obvious that it took him only
a minute to assess the condition of the platform.[48] Mr. Lewis did not climb up to the 17- foot platform
to install the spark rod because he felt the floor opening made it unsafe and
Calpine policies forbid working in an area where there was an uncovered opening
unless the opening was covered or barricaded.
(Tr. 571-73, 578-81, 654, 661-62, 666, 670, 679-80; RX-MM-E).
At
the end of his shift on the morning of December 21, Mr. Lewis informed the next
shift’s LMO, Mr. Lutz, that the platform surrounding the combustion chambers
was unsafe for travel because it had unguarded floor openings.[49] Mr. Lewis did not work on December 22,
2010. Mr. Lewis testified that, “to the
best of [his] memory,” Mr. Narkin was present when he told Mr. Lutz about the
openings in the platform.[50] (Tr. 533, 581, 587, 671-75). Mr. Lutz confirmed that Mr. Lewis told him
about the missing grates in the catwalk platform that morning. Mr. Lutz believed Mr. Narkin was in the room at
the time, but he was not “100% sure.” [51] (Tr. 461-63, 541-42, 533-38, 550). However, Mr. Narkin testified he was not advised
of the platform’s condition by Messrs. Lewis or Lutz on the morning of December
21. (Tr. 1488-89).
On
the December 21 night order, Mr. Narkin again included the task to install a
spark rod in CT-6’s east combustion chamber.[52] The December 21 night order carried over this
task from the previous night, with the added phrase: “[i]f tarps and Siemens are not in the way.”[53] Mr. Narkin was told to add this phrase, but
he could not recall who told him to do so.
Mr. Narkin testified he did not question the meaning of the phrase
because it seemed very clear. To him it
meant that the tarps covering the turbine were off and that Siemens’ “people”
and “stuff” were gone.[54] He testified that the “tarps were gigantic. And for them to not be in the way, they would
have to be off. They were huge.” (Tr. 166, 1006-08, 1485-88, 1517-18; JX-XIII)).
Mr.
Lutz testified that when BEC operations staff changed shifts there was usually a
discussion between the shift LMOs to pass along operational and safety
information to the next shift.[55] If Mr. Lutz could not attend he would
generally have someone fill in for him. Mr.
Lutz also testified that for his December 21 day shift, he left a few hours early
and was not there to tell the next shift’s LMO about the condition of the
platform.[56] The decedent was the LMO for the December 21
night shift. (Tr. 544-47).
Mr.
Rice’s last shift at the BEC plant was the night of the accident. He left before the end of the shift, at
approximately 2:00 a.m. He left earlier
than normal because Siemens had finished the technical aspects of the job and
was performing clean-up work for the remainder of the shift, which ended at
3:30 a.m.[57] Only Siemens’ employees were in CT-6 between
2:00 a.m. and 3:30 a.m. on December 22.
(Tr. 937, 940, 971, 980-81).
The Accident
Raymond
Lutz arrived at the BEC facility at about 5:15 a.m. on Wednesday, December
22. When he arrived, he was told by
other Calpine employees that they were looking for the decedent.[58] The decedent’s body was discovered in CT-6 a
few minutes later.[59] Mr. Lutz then went to CT-6 and saw the
decedent lying on the concrete floor near an access ladder leading up to the
northwest part of CT-6’s west combustion chamber.[60] He testified that the area was “kind of
shadowy.”[61] Using a flashlight and not wanting to move the
deceased, Mr. Lutz concluded that the deceased had perished. (Tr. 483-91, 496; RX-MM).
On
December 22, 2010, Mr. Varga reported to work at about 5:30 a.m. and went
directly to CT-6 when he learned of the accident and saw the deceased lying on
his belly. Mr. Varga testified that it
was “rather dark” inside CT-6 and he used a flashlight to see better. He testified that the deceased’s legs were on
either side of the access ladder that led to a combustion chamber with his
crotch pressing very tightly at an elevated level against the access ladder’s
left upright. Mr. Varga agreed that it
was “very apparent” that there were holes in the catwalk platform. He further agreed that he would have worn a
harness for safety reasons if he were to have ascended to the catwalk platform.[62] He also testified that the deceased’s head was
a couple of inches from the right upright of the shorter ladder that led to the
IGV platform. Mr. Varga testified that
one of the openings in the platform surrounding the combustion chamber was
“pretty much right above” where the decedent’s body was discovered.[63] He testified that he did not recall seeing any
tarps covering the combustion chambers. He
was at the north side of the west combustion chamber for less than five
minutes. (Tr. 695-97, 708-09, 725-26, 731-32,
737-38; RX-MM-F).
Coroner
Lysek[64]
arrived at the BEC facility between 6:00 a.m. and 7:00 a.m. to investigate the
reported death of an employee.[65] Upon arrival he was directed to CT-6. Mr. Lysek ascertained that the lighting was the
same as it would have been when the decedent entered CT-6 a few hours
prior. He testified the lighting in CT-6
was “adequate enough that I could look up and see the grating and make out
everything” and that he could clearly see the missing grates which were “leaning
against the railing” on the catwalk; he could see this without a flashlight or
other type of lighting device. (Tr. 1588-92,
1607, 1651-54, 1718-19).
Coroner
Lysek explained that on the day of the accident he observed the body and the
area surrounding it.[66] He testified that the decedent’s gloves were
not misplaced and were on each hand properly.[67] There were no tears in his jacket and it
“appeared perfectly fine.” He further
testified that decedent's head was lying face down on the concrete floor positioned
about an inch or two from the short access ladder (identified with the letter
“D” on RX-MM-I) with seven steps leading to the lower platform (also referred
to by Coroner Lysek as a catwalk) to the east (identified with the letter “E”
on RX-MM-I). There was a wet area on the
concrete floor that extended from the west wall over to the west side of the
combustion chamber. Coroner Lysek
described the lower platform as a metal grate walkway about three to four feet
wide, about seven feet off the ground.[68] Two bars, a lower bar and an upper bar,
protected and confined the lower catwalk’s space. There was a gate atop the short access
ladder that had to be opened to stand on the catwalk. He testified that the catwalk extended to the
combustion chamber’s south side. Immediately
north of the short access ladder, he described an area where there were two
six-inch I-beams, one north and one south, that extended from left to right
from the lower catwalk, and a catwalk to the left and west side. He testified that there was a small section of
particle board (also referred to as composite plywood) over the southern
I-beam. He testified that there was
another steel grated platform area that he identified at “H” on RX-MM-I, to the
left of the particle board (looking north), where there was another ladder that
extended from the floor where the deceased was found up to a platform that was
about the same elevation as the lower catwalk at RX-MM-I at “E”. The
distance from the particle board to the lower platform ladder at “D” was very
short. (Tr. 383, 1597-1610, 1623-26, 1647-49, 1671-72,
1731; JX-XXXIV, RX-L, RX-MM-I).
Coroner
Lysek testified that the west combustion chamber was “obviously under
construction” with various light stands and tools set about the walls. Upon entering, he saw that “the top of that
whole chamber was tarped with a very heavy green tarp.” He saw two sections of grate missing from the
upper platform (also referred to herein as the “upper catwalk”) that surrounded the west combustion chamber,
one on the south side that he identified as “I” on RX-MM-I and another on the
north side that he identified as “J” on RX-MM-I.[69] He also saw areas of yellow caution tape
hanging downward from the upper platform walkway. (Tr.
1605-07, 1654, 1718; RX-MM-I).
Coroner
Lysek took photographs of the area surrounding and above the location of the
body. He examined the nearby lower
platform which was about seven feet above the floor, the higher, upper platform
(where the grated floor sections were missing) which was 17 feet,1 and 31/32 inches,
above the floor (hereinafter any reference to “17 feet” or “17-foot” is
referring to an actual height of 17 feet, 1 and 31/32 inches above the floor), and
the corresponding access ladders for potential evidence. In an effort to identify any evidence that
might suggest the origin of where the deceased fell from, he climbed over a three
to four foot high railing that partitioned the lower platform at “H” from the
lower platform at “E” identified on RX-MM-I,[70] and
another railing on the east, right side of the lower platform. He then carefully walked across the two
I-beams using his left foot on the northern I-beam and right foot on the
southern I-beam and climbed over another railing in order to reach the lower
platform at “E” identified on RX-MM-I.[71] Using the caged access ladder at “B”, he then
climbed to the upper platform and looked down through the hole on the catwalk
and saw two pieces of grating that fit the two openings leaning up against the
railing at the west side of the west combustion chamber. (Tr. 161, 333-34, 1597-1613, 1622, 1630-31,
1715; JX-XIV, at p. 10, JX-XVI, at p. Calpine000089, JT-XXXIV, RX-MM-I).
During
his testimony Coroner Lysek described the opening in the upper catwalk platform
that was closest to, and when climbing up to the left of, the caged access
ladder.[72] He testified that he would expect there to
have been contact between the body and the opening’s metal surfaces if someone
of the decedent’s size had fallen through.
He found no physical evidence to indicate the deceased had fallen
through or near the platform opening.[73] Also, the body’s location was not directly
below the opening, which made it improbable he fell from the upper catwalk
platform.[74] He testified that the lower seven foot high platform
at “E” was “directly above the body.” Coroner
Lysek said that he used a very accurate Leica DISTO meter, D-8, to measure that
the distance from the concrete floor to the bottom of the upper catwalk was 17
feet, 1 and 31/32s inches. (Tr. 1617-19,
1622-23, 1633, 1642, 1652, 1683-85, 1710-11; JX-XVI, JT-XXXIV, RX-MM-I).
Coroner
Lysek stated that the deceased’s body was removed and that his office personnel
cleaned up blood beneath the deceased’s head before the OSHA COs arrived at
CT-6. He also testified that the
deceased’s cell phone located near the decedent’s head and hard hat may have
removed before the COs arrived at the accident scene. He further testified that a small silver
colored ignition fixture was found in the decedent’s coat or shirt pocket,[75] as
well as papers in his pocket of work that was done or checked off. Coroner Lysek rendered his initial
investigative findings and completed the deceased’s death certificate on
December 23, 2010. He reported the cause
of death as “Blunt Force Head Trauma” and the manner of death as an
“Accident.” His initial investigative
findings did not include rendering an assessment as to the origin of where the
deceased fell from because of a lack of evidence.[76] Coroner Lysek testified that he could not tell
if the decedent fell while on the ladder leading to the 17-foot platform (at
“B”, RX-MM-I) or the ladder leading to the lower level platform (at “D”,
RX-MM-I). He further testified that the
decedent’s body was about four feet north of the 17-foot platform opening and
since he fell straight down and his body did not move he fell from above where
he was and not through the opening in the 17-foot platform. He testified that “it’s unlikely that he
could have fell through the opening.” He
also testified that the Decedent “very likely” fell from the ladder identified
as “D” leading to the lower platform at “E”, RX-MM-I.[77] (Tr. 1637-39, 1648-49, 1664-65, 1668-70, 1681,
1684-85, 1722-33; JX-XVI at CALPINE000074, RX-L, RX-MM-I).
Detective
Iatorola took many photographs while at the accident site on December 22, 2010
at about 7:00 a.m. Several of these
photographs have been sealed by Court order due to their graphic nature. Photograph JX-XVI, at p. Calpine000083, shows
the platform opening that was nearest the caged ladder that led to the 17-foot
platform, as well as the caged ladder and a piece of dangling tape, at the
north side of the west combustion chamber of CT-6.[78] (Tr.
1636; JX-XVI).
OSHA
COs Tricia Weisenberger and Nicholas (“Nate”) Burgei arrived at the BEC
facility at about 9:30 a.m. on December 22.[79] Before arriving at the accident site, it was
CO Weisenberger’s understanding that an employee had fallen through an
opening. They spent from about an hour
and a half to two hours at the BEC facility.
CO Weisenberger testified that it was fairly dark when they entered
CT-6.[80] Mr. Killgore escorted the COs to CT-6, where
the coroner and Mr. Narkin were at that time.[81] The coroner showed the COs the location of
the body because, by the time they arrived, it had been moved and the blood was
washed away.[82] CO Weisenberger made no detailed notes of what
the coroner told her.[83] CO Burgei did not make any handwritten notes
or sketches during, of after, the inspection. He sent CO Weisenberger an email on December
22, 2010, at 12:59 p.m., that stated that, from what he could remember, a
worker fell from about 17-feet through an open hole in the catwalk.[84] He also stated in the email that “Yellow
caution tape was tied to the guard railing around all four open holes, but the
tape had been cut or ripped. It was
still tied to the railing, but dangling.”[85] CO Burgei testified that he did not know of
any facts that supported the assertion that the deceased was ever up on the
catwalk, or that he fell.[86] AD Kulp testified that CO Burgei’s assertion
in the email that Siemens had replaced the catwalk and installed grates during
the December 21, 2010 night shift was “found not to be true.” She agreed that Siemens had replaced the
catwalk during the December 21, 2010 day shift.
(Tr. 128-32, 157-59, 162, 223, 284-86, 309, 326, 421, 434-35, 775, 829-32,
860, 895, 905-09, 1167-69, 1637, 1704; GX-7, RX-D).
CO
Weisenberger could see that the catwalk platform surrounding the combustion
chambers had missing floor grates.[87] CO Burgei took 19 photographs during the
inspection.[88] Photograph GX-1-8 taken by CO Burgei shows the floor
opening to the left of the gate on the upper platform. It also shows a tarp that reached nearly down
to the walkway at the west combustion chamber in the area of the platform
opening.[89] Photographs GX-1-11 and GX-1-12 also show the
floor opening at the upper platform to the left of the gate. Photograph GX-1, at p. 1 (first exhibit
photograph), showed yellow caution tape hanging down near, but not going across,
one of the 17-foot platform openings on the south side of the west combustion
chamber.[90] CO Burgei, along with Calpine’s Environmental
Health and Safety person, Al Fisher (also referred to as Fischer), used the
taller access ladder to climb to the 17-foot platform surrounding the
combustion chambers.[91] He testified that neither he nor CO
Weisenberger measured the platform height, the opening in the platform, the
ladder, the distance from the swing gate’s right post to the opening, or the
deceased’s distance from the area below the opening.[92] CO Burgei did not project a perimeter of the upper
platform opening straight down to the floor to see what was directly beneath
the opening on the north side of the west combustion chamber. He did not look for or find any physical
evidence to show that the decedent could have fallen through the platform
opening. CO Weisenberger did not
check the ladders for signs of blood, body tissue, clothing material, fiber, or
scuff marks.[93] (Tr. 132, 152, 160-63, 283-84, 301, 777-83,
813, 849-51, 857, 876-77, 915-18, 1149; GX-1, at pp. 1-19, RX-M).
CO
Weisenberger identified two combustion chamber areas [BK-1 and BK-2, also
sometimes referred to as the east (BK-1) and west (BK-2) combustion chambers]
in CT-6 that were covered by tarps on December 22, 2010. The OSHA-1B Worksheet indicated that the
tarps did not cover the catwalk area or the ladder leading to it. OSHA contends that the deceased was exposed
to an opening in the elevated walkway surrounding a Unit 6 combustion
chamber. CO Weisenberger testified that
she believed that the deceased died from a fall, but OSHA is not sure if he
fell through the platform opening.[94] CO Weisenberger testified that the standard
at issue called for either a guardrail or someone to constantly attend to the
17-foot platform opening. (Tr. 155-56,
241, 277-78, 299-300, 304, 317, 396-99, 1012, 1151, 1409; JX-III, at p. 2,
GX-1-8, GX-17B, RX-E, RX-RR).
The
COs left CT-6 and continued their discussions with Mr. Narkin in the control
room. CO Weisenberger testified that Mr.
Narkin told her a surveillance video showed the decedent walking in the
direction of CT-6 from the maintenance shop at 3:32 a.m. that morning. She
believes that he also told her that OMT John Horvath found the deceased
sometime after 5:15 a.m. (Tr. 164, 335-36,
381-82, 483-84, 495, 1669; JX-XIV, at p. 10, RX-L, at pp. 1-2).
During
interviews of Siemens’ employees conducted by CO Weisenberger in early 2011,
she was told that Siemens’ employees were working on the lower area of the
combustion chamber, not on the 17-foot platform, during the December 21-22,
2010 night shift. On about January 11,
2011, Mr. Gautille told CO Weisenberger that Siemens’ employees had removed
forty percent of the catwalk and forty percent of the walk around platform so
that they could use a crane.[95] He told her that Siemens personnel left CT-6
at 3:30 a.m., December 22, 2010, and that they had been working on the “bottom
part of [the] combustor – not on [the] platform.” He also told her that Siemens’ December 22,
2010 day shift was to replace the missing portions of the 17-foot catwalk
comprising two openings at each combustion chamber. (Tr. 343, 375, 412; JX-II, at p. 3, JX-XV, at
pp. 4, 6-7).
Mr.
Killgore also took several photographs of the combustion chambers and the upper
platforms that surrounded the combustion chambers in CT-6 after the coroner
departed and while the OSHA compliance officers were on site on December 22,
2010. (Tr. 1405; JX-XXXIII). Photograph JX-XXXIII, at p. 3, shows the upper
platform opening that was nearest the caged ladder that led to the 17-foot
platform, as well as the caged ladder and a piece of dangling tape, at the
north side of the west combustion chamber of CT-6.[96] Photograph JX-XXXIII, at p. 9, shows
yellowing cautionary tape hanging down where there is an upper platform opening
and a piece of green tarp over the combustion chamber. The photograph at JX-XXXIII-A shows a piece
of grating leaning up against an outside railing and the photograph at
JX-XXXIII-B shows the upper catwalk leading from the west combustion chamber to
the east combustion chamber, and yellow cautionary tape and a piece of green
tarp near an upper platform opening at the south side of the east combustion
chamber.[97] Other photographs at JX-XXXIII, at pp. 7-9,
12-13, taken by Mr. Killgore show yellow caution tape tied to fixtures at
various places on the 17-foot platform. Mr.
Killgore testified that he said to the OSHA compliance officers that they were
not wearing any fall protection. He then
went up first to the west combustion chamber’s 17-foot platform and put a piece
of grating down at the opening to the left of the top of the ladder.[98] He further testified that the opening was
visible from the ground level. (Tr. 1405-17;
JX-XXXIII, GX-1, at p. 13).
AD
Kulp testified that she made the final decision to issue the citation to
Calpine.[99] (Tr. 1049-50, 1128-34; JX-1). She stated that the basis for the citation
was the assignment “to go into an area that involved being exposed to a
temporary floor opening. That that potential existed without the employee receiving any type of
special instructions, being provided any type of fall protection and training
specific to the work environment.” (Tr.
1314). AD Kulp agreed that OSHA had no
evidence that the decedent was on the upper catwalk platform on December 22 and
that the evidence was inconclusive as to where he was when he fell.[100] (Tr. 1170-72, 1293). AD
Kulp conceded that she received information during the course of the
investigation that it was a “possibility” the decedent may have entered CT-6 to
merely assess the work area.[101] She testified that the coroner told her in
March, 2012, that the deceased’s injuries could have been consistent with
falling from any location within CT-6’s work area. (Tr. 1111-13, 1294).
Coroner
Lysek testified that the reference in the coroner’s report that the body was
beneath the upper catwalk platform could be misunderstood.[102] He clarified that it referred to his
observation that the upper catwalk was generally above the body; it did not
mean the body was directly below the area of missing grates in the upper
catwalk platform. He stated that the
body was about four feet away from the area directly below the upper platform
opening.[103] (Tr. 1732-33).
Coroner
Lysek returned to the BEC facility with Dr. Edward Chmara in February 2012 to
walk through the area of the accident to see if he could determine where the
decedent was when he fell. (Tr. 1118, 1695-97). Coroner Lysek, after both his initial and
follow-up visits to CT-6, concluded that:
[T]he evidence that is there: where the blood impact
spatters were, where the body was and the position of it is, I can say he did
not move. It's not as if he fell, was in
pain and rolled or anything of that nature.
Where he hit the ground he stayed, he did not move. And – it’s – to me logical he couldn't have
fell from the turbine because of the distance away. He would have had to somehow swung or moved
his body a distance north to get in the position he was. It’s not a direct fall down and if fitting
through that hole he would have had to have had also some other evidence,
whether it would have been on the metal surrounding that, or the bottom . . . I
don't specifically know where he fell from, but I could say with – he
reasonably he could not have fell from one area because of where his body was,
that I think it would have had to have come from [another] area.[104]
(Tr.
1705-1706). Coroner Lysek testified that
it was “very likely” that the decedent actually fell from the access ladder
that went up to the shorter platform [also referred to sometimes as the “Turbine”
deck].[105] He
also testified that “I also think that the area precludes a high elevation
fall, and I didn’t feel that he could have gotten very high, he would have had
to have fallen from a distance of approximately seven (7) feet or less, just
based on the limitations of the area.”
Coroner Lysek further testified that the injuries to the decedent “could
be consistent with him falling from a standing position and striking something,
or from a lower level.” (Tr. 1682, 1707,
1730-31).
Dr.
Chmara was the forensic pathologist who performed the autopsy on the decedent
on December 23, 2010.[106] One of his tasks includes determining the
cause of a death.[107] He testified that at the time of the autopsy,
it had been conveyed to him that the decedent “might have fallen through a part
of a catwalk.”[108] He determined that the death was accidental
and from multiple blunt force injuries.[109] He testified that the broad area of the
decedent’s abrasion at the top of his head was “absolutely classic for a head
impacting a large flat surface, i.e.
a concrete floor.” Dr. Chmara further
testified that the decedent “fell virtually straight downward and that’s why
this is right at the top of his head.” He
elaborated that as the decedent’s head hit the ground, his legs spilled over as
if trying to do a somersault forward, but your head stops everything and your
legs continue to go. He clarified that
he had not visited the scene of the accident when he wrote the initial autopsy
report. The coroner’s office received
the autopsy report in July, 2011. (Tr. 1670,
1680, 1719, 1738-46, 1750-54, 1770; RX-L).
Dr.
Chmara’s first visit to BEC’s facility was in in February 2012 when he and
Coroner Lysek walked through CT-6 at the request of Calpine’s attorneys.[110] Prior to this visit, Dr. Chmara and Coroner
Lysek reviewed simulations of possible accidental fall scenarios that had been
prepared by Calpine’s expert C. Brian Tanner. They spent about an hour and a half at the
accident scene. After the visit, Dr.
Chmara reviewed the photographs taken the day of the accident and the autopsy
photographs. After visiting the scene,
Dr. Chmara testified that “it didn’t make sense that the body would fall
through those catwalks and land where it was positioned” as shown in the
photographs. He further testified that
he “couldn’t make sense of how the body would get five to six feet over further
if the body fell straight through from there [17-foot catwalk opening where
grate missing identified at “A”, RX-MM-J] and hit nothing on the way.” Dr. Chmara testified that he “did not think
it was possible in any way, shape or form that that [decedent’s] body, …, fell
through the opening in the catwalk and then – an unobstructed fall to the
ground below from what was a height of 17 feet to the bottom of the
platform. It just – it didn’t happen
that way.” [111] Dr.
Chmara testified that, instead, he concluded that the deceased:
[w]as climbing up the ladder going to the 17-foot walk, I
mean this is my medical opinion to a high degree of medical certainty, for the
record. He was climbing up the ladder, the backside of
the ladder, and tried to step over to the platform on the other side. The only way that he could be in the
compromised position, in my opinion, to have the legs literally straddling that
– the uprights of that other ladder, is that he somehow at some point was
holding the ladder, climbing up the backside, tried to step over to the other
platform by putting his left leg across in front of his right and at some point
lost his balance, lost his grip, and at that point fell straight down. (Tr. 1771).
Dr. Chmara testified that he
discussed amending the autopsy report with Coroner Lysek, but since he was no
longer with Forensic Pathology Associates, he did not have the opportunity to
amend any report that came from there.[112] In late March, 2012, Coroner Lysek met with
AD Kulp in his office for between one to two hours during which he reviewed about
two hundred photographs of the accident
scene on a large screen display. The
focus was on photographs of where the body was with respect to the ladders,
catwalks, including the two lower catwalks.
Coroner Lysek testified that during this meeting he explained that his
initial report did not identify where the decedent fell from and that the
wording “fell from catwalk” did not mean fell from the 17-foot higher catwalk,
the low catwalk, or the beams. He made
it clear, that he did not “think that the [decedent] fell from the upper 17-foot
catwalk” because of the body’s location, blood impact spatters, and the body’s
distance from the turbine; as well as the lack of material evidence showing he
fell through the catwalk opening.
Instead, he explained to AD Kulp that the decedent fell in the area
between “B” [tall 17-foot access ladder at RX-MM-I] and “D” [ladder leading to
lower level platform at RX-MM-I]. (Tr.
1689-91, 1696-1707, 1753, 1756, 1760-66, 1770-74; RX-MM-I, RX-MM-J).
Safety Program
CO
Weisenberger testified that she conducted an audit of Calpine’s safety programs
and she did not recall finding any deficiencies in Calpine’s fall protection
program.[113] (Tr. 367, 372, 389, 392-404, 416-18, 1254 ; JX-II,
at p. 5, RX-J, at pp. 4-5, RX-Q, RX-PP).
Calpine’s Contractor/Visitor Safety Orientation policy called for BEC
on-site contractors, such as Siemens, to “provide and keep in good repair,
fences, temporary sidewalks, guard rails, barricades, warning lights, signs and
other safeguards necessary to protect all personnel and the public from
injury.”[114] AD Kulp agreed the CO’s file notes indicate that
Calpine “has an extensive safety and health program and training on hazards.” (Tr. 395-96, 399-400, 1307-08; RX-Q, at p. 4, JX-II).
In
her OSHA-1B Worksheet for Siemens, CO Weisenberger stated:
Siemens employees did not implement the directed
administrative control of placing warning signage and tape across the ladder
access points. This control measure
would have provided definitive, easily identifable (sic) warning to all
employees accessing the upper catwalk.
This would have indicated the need to use conventional fall protection
when working near the unguarded edges. A
combination of signage and warning tape, as described in SPM-39 instruction
under sections 5.2 and 5.3 would have been a sufficient warning for Calpine
employees.
(Tr. 405-06; R-J, at pp. 2, 4).
Mr.
Narkin testified that his staff, including the deceased, was required to
complete formal safety training modules every month.[115] They were also required to do a pre-job
safety checklist before each job commonly done in the plant. Mr. Narkin testified that employees were
trained to first assess jobs for safety and that he put a system in place to
ensure all jobs were done safely. He
also acknowledged that Respondent’s Fall Protection policy called for
supervisors to “[p]erform a fall hazard assessment for each job and determine
the proper equipment and procedure for that specific task.” He described Calpine’s safety program as
“extremely good” with a very strong safety culture. (Tr. 998, 1442, 1449-53, 1474, 1500; RX-PP).
Mr.
Miller testified that Calpine had monthly safety training and a monthly safety
committee meeting, and that each employee received a copy of an employee safety
policy handbook. Mr. Miller stated
specifically that BEC’s safety policy would require an employee working near a
floor opening to wear fall protection or barricade the opening.[116] (Tr. 1533-35, 1541-42, 1565).
Mr.
Miller also testified that, as BEC’s plant manager, he reviewed the monthly
safety training records to determine which hourly employees qualified for the bonus
training incentive payments. He
estimated that the required training for an employee adds up to about 60 to 80
hours annually. In addition, there was a
peer-to-peer safety evaluation program in which an employee observed a
co-worker and noted safety compliance issues on the evaluation form. The purpose of this evaluation was to promote
a general sense of responsibility for safety among the employees. An employee was required to complete at least
one observation each month to qualify for the monthly bonus. Further,
Calpine retained an outside safety consultant, TekSolv, to conduct safety
audits and training at BEC in about July 2010.
(Tr. 1533-35, 1548-51, 1555-6; RX-EE, RX-LL).
Mr. Lewis testified that every year he was
employed at BEC, every employee at the plant was trained annually on safety policies
and procedures for an estimated annual total of 40 hours. The training topics included ladder safety,
fall protection, walking-working surfaces, hazard identification, personal protection,
barricading, and incident protection training.[117] Mr. Lewis noted that every employee received
a copy of the employee safety handbook. He
testified that as a LMO, he considered himself a supervisor of his crew,
responsible for enforcing all of Calpine’s safety policies and procedures. He also noted that employees who had the risk
of falling four feet or more were trained on fall protection procedures.[118] Mr. Lewis stated that Calpine employees’ bonus
compensation was tied to their adherence to the safety requirements, safety
programs and safety training.[119] (Tr. 603-25, 1525-26; RX-JJ, RX-PP).
Mr.
Narkin testified that “every employee knows that they're empowered to either
stop or not start a job, when they discovery a safety issue, and that happens
frequently.” He testified Calpine employees
regularly complete a job safety audit (“JSA”) or job safety briefing (“JSB”)
checklist before starting a job identified on a night order and the job is
“scrubbed” if the employee sees “something that he can’t do.”[120] He said that employees were disciplined with coaching
sessions, written reprimands, and, eventually, termination when they did not
comply with safety policies. (Tr. 999, 1443,
1459-62, 1490-91, 1518; JX-XIII).
Mr.
Narkin further testified that he prepared a pre-outage list of approximately 16
safety items, which were descriptions of situations that had caused problems at
power plants during outages. He stated
that he went over this pre-outage list before the overhaul project began and that
he emailed it to his employees twice before the overhaul started. He also stated that one of the items on the
pre-outage list was that fall protection was required at heights greater than
four feet. (Tr. 990, 1451-52. 1480-82,
1509; GX-11).
The Decedent
Messrs.
Lewis, Lutz, and Varga began working at BEC the same year as the decedent –
2002. (Tr. 441, 483, 567, 601, 706). Mr. Lutz testified that it was the
decedent’s habit to always wear his gloves while climbing a ladder, and that he
did not usually wear them while performing a task. (Tr. 508).
CO Weisenberger was told during her employee interviews that the
decedent's routine was to wear his gloves while climbing the ladder. He would remove his gloves after closing the
gate behind him and then “do what he had to do.” (Tr. 341, 383, 386, 388, 508-10; JX-IV, at p.
3).
Mr.
Varga testified that the decedent had a “great attitude about safety” and
always wore his personal protective equipment; he was not aware of him working
unsafely. (Tr. 706-07). Messrs. Lewis and Lutz also testified that the
decedent was very safety-conscious. (Tr.
483, 510, 601-02, 671).[121] Mr. Lewis further testified that he did not
believe the decedent would knowingly expose himself to danger by climbing up to
the combustion chamber when there was an opening in the platform. (Tr. 670-71).
Mr.
Miller testified that the decedent’s 2003 performance evaluation included a
rating of “exceeds expectations” for safety.
He further testified that his observations of the decedent’s performance
were consistent with that evaluation. Mr.
Miller explained that the decedent “tried his hardest to complete the tasks he
was given. He wanted to make sure he
followed all the policies and procedures when doing so. Very conscientious, a very good work ethic,
which lines up with the ratings on this particular performance evaluation.” He testified that the deceased appeared “a
little more distracted” and “a little flustered” at about 6:30 p.m., December
21, 2010, at a time when some fire alarms were “going off.”[122] (Tr. 1539-41, 1563-64, 1677-78; RX-S).
Cited Standard
The
Secretary cited Calpine for violating 29 C.F.R. § 1910.23(a)(7)[123],
which states that:
(7) Every
temporary floor opening shall have standard railings, or shall be constantly
attended by someone.
Secretary’s Burden of Proof
To
establish a violation of an OSHA standard, the Secretary must show by a
preponderance of the evidence that: (1)
the cited standard applies; (2) the terms of the standard were violated; (3) the
employer knew, or with the exercise of reasonable diligence could have known,
of the violative condition; and (4) one or more employees had access to the
cited condition. Astra Pharm. Prods.,
9 BNA OSHC 2126, 2129 (No. 78-6247, 1981), aff’d in relevant part, 681
F.2d 69 (1st Cir. 1982).
Discussion
Whether
Calpine was prejudiced by OSHA’s Inspection
Calpine asserts that it was
“severely prejudiced” because OSHA did not follow its own procedures for an
inspection. In particular, Calpine
states that because the COs did not take measurements at the accident scene or
interview the first responders the investigation was inadequate.[124] (R. Br. 81-82). This argument fails for two reasons. First, Calpine has not provided information
to show how it was prejudiced. Most
importantly, Commission precedent has long held that OSHA’s internal guidance
documents do not provide rights or defenses to an employer. Mautz
& Oren, Inc., 16 BNA OSCH 1006, 1009-10 (No. 89-1366, 1993) (finding
primary purpose of OSHA Field Operations Manual “is not to give employers
particular rights or defenses in adjudicatory proceedings.”). Although the Court agrees with Calpine that OSHA’s pre-citation
accident investigation was not thorough in all respects, the Court finds there is no evidence of
prejudice to Calpine from OSHA’s investigation.
Whether
the Secretary Has Established the Alleged Violation
Based
on the record, the Court finds the cited standard applies. The evidence shows there was an opening in
the 17-foot, 1 and 31/32 inches platform to the left of the caged ladder measuring
about 32 inches on both its right and left side and 12 inches or more at its
smallest dimension. The Court finds that
the opening for which Calpine was cited meets the applicable definition of a
“floor opening.”[125] (S. Br. 13-14; Tr. 575, 776, 778-79, 1615;
1717; JX-XVI, at Calpine000083, at “A”, JX-XXXIII, at p. 3, GX-1, at pp. 8, 11,
12). The evidence also establishes that
the upper platform opening was temporary in nature. (Tr. 18-19; 1013-14).
Calpine
asserts the standard does not apply because it had no control over CT-6’s upper
catwalk platform during the outage; instead, its contractor, Siemens, had
exclusive control. Therefore, Calpine
asserts that Calpine was not responsible for the upper platform’s condition. (R. Br. 65-66). When an employer neither creates nor controls
the hazardous condition at a multi-employer worksite, it may defend against a
citation by showing that it protected its employees by taking reasonable
alternative measures or that it could not reasonably have known of the
hazardous condition.[126] Capform,
Inc., 16 BNA OSHC 2040, 2041-42 (No. 91-1613, 1994) (citations
omitted). The Commission has held that
the employer’s conduct is viewed in its totality and “whether a reasonable
employer would have done more.” Id. at 2041-42.
Calpine’s
multi-employer worksite defense and argument fails, as the Court finds that it
did continue to have sufficient control in CT-6.[127] Calpine owned the CT-6 building. Calpine, through TMG, had staff present in
CT-6 dedicated to the oversight of Siemens’ work. Calpine’s employees still accessed the
building during the Siemens’ overhaul. Mr.
Narkin acknowledged that employees had to often go to elevated platforms to
perform maintenance during overhaul outages.
BEC employees had to perform certain tasks that Siemens was prohibited
from doing. Calpine also performed
safety audits of Siemens’ work in the CT-6 building. The Court finds that Calpine had sufficient control
of its own CT-6 facility to the extent that the standard applies. (Tr. 643-44, 1022-23, 1807-08; GX-11).
Under
the Act, an employer has a duty to protect its own employees from workplace
hazards. See 29 U.S.C. § 654(a); Baker
Tank Co., 17 BNA OSHC 1177, 1180 (No. 90-1786, 1990) (Respondent had legal
responsibility for the safety of its own employees). That duty may not be contracted away to third
parties. See Bianchi Trison Corp. v.
Chao, 409 F.3d 196, 209 & n.21 (3d Cir. 2005); Summit Contractors, Inc., 23 BNA OSHC 1196, 1207 (No. 05-0839,
2010) (finding employer may not contract out of its duties under the Act), Baker Tank Co., 17 BNA OSHC at 1180 (finding
Respondent could not contract away its legal duties to its employees or its
ultimate responsibility under the Act by requiring another party to perform
them). When an employer denies liability
on the ground that it lacked control over hazardous conditions to which its own
employees were exposed, it must show, first, that it had no ability or
authority to abate the hazard as required under the cited standard; and second,
that it took reasonable alternative steps to protect its employees from the
hazard. See Rockwell Int’l Corp., 17 BNA OSHC 1801, 1808 & n.11 (No.
93-45, 1996) (consolidated) (establishing the multi-employer worksite defense,
an employer must prove three elements, including it did not control the
violative condition, so that it could not itself have performed the action
necessary to abate the condition, and it took all reasonable alternative
measures to protect its employees from the violative condition). The employer bears the burden of establishing
this multi-employer worksite defense. See Grossman Steel & Alum. Corp., 4
BNA OSHC 1185, 1190 (No. 12775, 1976).
Calpine
has not met its burden of establishing this multi-employer worksite defense in
this case. There is no evidence that
Calpine lacked the authority or ability to prevent its employees from accessing
the southern portion of CT-6, or to assign someone to constantly attend to the 17-foot
high platform when it contained unguarded openings, during those periods of
time when Siemens’ work crews were absent from the worksite, or otherwise. As the owner of the CT-6 building, Calpine
could have taken whatever steps it deemed necessary to protect its employees
when they entered CT-6 to potentially perform work there. See Cent.
of Ga. R.R. Co. v. OSHRC, 576 F.2d 620, 624 (5th Cir. 1978) (“If an
employer does contract with a third party to maintain safe conditions, it is to
be presumed that the employer can enforce the contract.”). Calpine had the authority and responsibility
to insist that Siemens comply with the requirements of § 1910.23(a)(7) during
those periods when Calpine employees would be performing tasks in the CT-6
building. Calpine had the ability to
abate the hazard. There is also no evidence
to show that Calpine implemented any reasonable alternative abatement measures. Calpine neither asked Siemens to abate the
hazard, nor attempted to abate the hazardous condition itself. Calpine could have elected to wait until
Siemens had totally completed its [Siemens] overhaul-related work in CT-6
before assigning any task, potential or otherwise, to any of Calpine’s employees.[128] Calpine could have prevented its employees
from accessing the southern portion of CT-6 during those periods of time when
Siemens’ work crews were absent from the worksite. The Court finds that Calpine does not qualify
for the exception set out in Capform;
therefore, the standard applies.
The Court further finds the
requirements of the standard were violated.
The standard specifies that a temporary floor opening must be either constantly
attended by someone or have “standard railings.” Both parties agree there was an opening in
the floor of the upper catwalk platform.
And, there is no dispute that there was no one was attending the floor opening
and that there was no railing around the opening at the time of the
accident.
Calpine argues, however, that it did
not know of the hazardous condition and that there was no actual or potential employee
exposure. The Secretary must prove the
employer either knew, or with the exercise of reasonable diligence could have
known, of the violative condition. Dun-Par Engineered Form Co., 12 BNA OSHC
1962, 1965 (No. 82-928, 1986). The
employer’s knowledge is directed to the physical conditions that constitute a
violation. Phoenix Roofing, Inc., 17 BNA OSHC 1076, 1079-1080 (No. 90-2148,
1995), aff’d without published opinion,
79 F.3d 1146 (5th Cir. 1996).
The
Secretary asserts that Calpine had constructive and actual knowledge of the
violative condition. She states that
Calpine could have known if it had made a reasonable, diligent effort to find
the hazard since the openings were readily apparent. She further states that Calpine had actual knowledge
through its LMOs -- Mr. Lewis and the decedent.
(S. Br. 20-21). The Court finds
the Secretary has met her burden for this element for the reasons that follow.
As the Commission stated in Automatic Sprinkler
Corp. of Am., 8 BNA OSHC 1384, 1387 (No. 76-5089, 1980), an employer “must
make a reasonable effort to anticipate the particular hazards to which its
employees may be exposed in the course of their scheduled work.” Further, the Commission has stated that “the
conspicuous location, the readily observable nature of the violative condition,
and the presence of [the employer’s] crews in the area warrant a finding of
constructive knowledge.” KS Energy Servs.,
Inc., 22 BNA OSHC 1261, 1265 (No. 06-1416, 2008) petition denied,
703 F.3d 367 (7th Cir. 2012) (citations omitted).
The
actual or constructive knowledge of an employer’s supervisory personnel can be
imputed to an employer, unless the employer establishes substantial grounds for
not doing so. Ormet Corp., 14 BNA OSHC 2134, 2137 (No. 85-531, 1991), citing Donovan v. Capital City Excavating Co.,
712 F.2d 1008, 1010 (6th Cir. 1983). The
criteria to determine who can be considered supervisory personnel is set out in
the Commission’s decision in Tampa
Shipyards, Inc., 15 BNA OSHC 1533, 1537 (No. 86-360, 1992) (consolidated) (citations
omitted).
An employee who has been delegated authority over other
employees, even if temporarily, is considered to be a supervisor for the
purposes of imputing knowledge to an employer.
The knowledge of crew leaders and
foremen has been imputed in prior Commission decisions. Id.;
Kerns Bros. Tree Serv., 18 BNA OSHC
2064, 2069 (No. 96-1719, 2000); Jersey Steel Erectors,
16 BNA OSHC 1162, 1164 (No. 90-1307, 1993), aff’d,
19 F.3d 643 (3rd Cir. 1994) (“[t]he actual or constructive knowledge of an
employer’s foreman or supervisor can be imputed to the employer.”).
The
Court finds an LMO is a supervisor for the purpose of imputing knowledge. The evidence shows that an LMO operated in
much the same way as a foreman. The
LMO’s duties include delegating tasks to the team and ensuring that safety training
was completed. Further, Mr. Lutz testified
that when the facility transitioned to Calpine ownership, shift supervisors
were eliminated and replaced with LMOs.
Mr.
Lewis testified that he knew of the platform openings approximately 24 hours
before the accident. He chose not to
complete the task on the night order because of the missing catwalk platform grates. Further, Mr. Lewis testified that he notified
both Messrs. Narkin and Lutz of the
catwalk’s condition. As the night shift
LMO, his knowledge is imputed to Calpine.[129] Mr.
Killgore testified that he worked the December 21, 2010 day shift and described
the activities accomplished by Siemens during that shift.[130] Also, Mr. Rice had seen Siemens’ Shift
Turner Report for December 21, 2010, at 5:00 p.m., December 21, 2010, many
hours before the accident and Mr. Killgore had firsthand knowledge of the
platform openings by 5:00 p.m., December 21, 2010. The
Court finds that the knowledge of the unguarded upper platform floor openings
of Messrs. Narkin, Lewis, Lutz, Killgore and Rice as of December 21, 2010 and
carried forward through to the early morning hours of December 22, 2010 is
imputed to Calpine.[131]
The
Court also finds that Calpine had constructive knowledge of the hazardous condition. Multiple witnesses testified that the
openings in the upper platform present from December 20 through the time of the
accident were clearly visible after entering CT-6. Mr. Narkin was aware that Siemens’ work in
the CT-6 was in progress. TMG
representatives were present in CT-6 with Siemens’ staff and attended daily
status meetings. Mr. Narkin could have
personally gone to CT-6 on December 21, 2010, or requested a status of the catwalk
platform’s condition through a TMG representative. Because the condition was easily seen and TMG
staff was in the vicinity, the Secretary has shown that Calpine could have
known of the condition with the exercise of reasonable diligence. See Revoli Constr. Co., 19 BNA OSHC 1682,
1684 (No. 00-0315, 2001) (“The test for knowledge is whether an employer knew,
or with the exercise of reasonable diligence could have known, of the violative
condition.” ); see also Sec’y of Labor v.
ConocoPhillips Bayway Refinery, 654 F.3d 472, 479-80 (3rd Cir. 2011). A hazardous condition that is “readily
apparent” due to its location in a conspicuous area will support a finding of
constructive knowledge, especially where employees are present in the area
where the hazard is located. See KS Energy Servs., Inc., 22 BNA OSHC at
1267-68; Kokosing Constr. Co., 17 BNA
OSHC 1869, 1871 (No. 92-2596, 1996).
Finally,
the Secretary must show that an employee was either actually exposed to the zone
of danger or that exposure was reasonably predictable. Consol.
Grain & Barge Co., 23 BNA OSHC 2055, 2065 (No. 10-0756, 2011)
(citations omitted). Had the Secretary
presented sufficient evidence to prove that the decedent had fallen through the
upper platform opening, then actual exposure would have been shown. There is insufficient evidence to show that
the decedent fell through the upper platform opening on the north side of the
west combustion chamber. The Court finds
that the decedent did not fall through the opening at that location. Instead, fully crediting the testimony of the
coroner and forensic pathologist, the Court finds that the decedent fell from
the area between the ladder leading to the lower platform that was between five
to seven feet in height at “D”, RX-MM-I, and the lower, un-caged portion of the
ladder at “E”, RX-MM-I, comprising not more than seven steps that led to the 17-foot
platform. The Secretary has not shown
the decedent was actually exposed to the hazard.[132] To the contrary, AD Kulp admitted that the
evidence was inconclusive regarding where the decedent was when he fell. The Court finds the coroner’s conclusion,
that it was more likely the decedent did not fall from the area of the hazard, is
persuasive. The coroner has extensive experience
in accident investigation. He found no
physical evidence to show the decedent fell through the floor opening. The Court further finds that the forensic
pathologist, Dr. Chmara, also concluded that the decedent did not fall through
the floor opening at the 17-foot platform.[133] The Secretary did not present evidence to
rebut the findings of the coroner or the forensic pathologist. The Secretary has not proven any Calpine
employee exposure to the upper platform floor opening hazard, actual or
otherwise.
The
predictability of exposure can be determined through “evidence that employees
while in the course of assigned work duties, personal comfort activities and normal means of ingress/egress
would have access to the zone of danger.” Phoenix, 17 BNA OSHC at 1079 n.6. Further, “[r]easonable predictability requires
more than a hypothetical possibility of exposure, though less than a
certainty.” Consol. Grain, 23 BNA OSHC
at 2066. There are several factors to
consider in determining what was reasonably predictable in this case. Calpine’s overall safety program, the nature of
the assigned task, the purpose of the night order, employee practices, and the decedent’s
work history are all relevant.
The
Secretary asserts that exposure is predictable based on the task to replace the
spark rod in CT-6. (S. Br. 16). Calpine
asserts that because the task was not listed as a priority and was conditional,
it cannot be used to show that it was likely an employee would be exposed to
the hazard. (R. Br. 26-28). As stated in Respondent’s brief, the test for
determining access to a violative condition includes a requirement that such
access be “reasonably predictable.” Consol. Grain, 23 BNA OSHC at 2065. “This requirement entails a demonstration
that employees will be, are, or have been in a ‘zone of danger.’” Id., citing Fabricated Metal Prods., Inc., 18 BNA OSHC 1072, 1074 (No. 93-1853,
1997). The Commission has held that it
requires more than a hypothetical possibility that an employee could come in
contact with the hazard. The Commission
in Fabricated Metal Products “emphasize[d]
that … the inquiry is not simply into whether exposure is theoretically
possible.” Id. In Consolidated Grain, the Secretary failed to show that it was
reasonably predictable that employees would be in the zone of danger, which the
court found to be in front of a rotating auger where employees could be exposed
to the in-running nip points of the auger.
Pursuant to the company’s policy, employees were required to stay behind
the rotating auger. The court noted that
while it was “not impossible that an employee could come in contact with the
in-running nip points of the auger, however, that is not the standard.” Consol.
Grain, 23 BNA OSHC at 2066. (R. Br.
at pp. 20-21).
The
Court finds that the evidence shows that the task to replace the igniter was a
low priority on the night order and that there was no pressure on the decedent
to complete this particular task during his shift. Further, the record shows that the lighting
conditions in CT-6 the morning of the accident were adequate to see the holes
in the upper platform from the building’s floor; an employee did not need to
climb a ladder to determine there was an opening in the upper catwalk’s
platform. Mr. Narkin’s December 21, 2010
night order had two expressed conditions that had to be met before the task to
replace the igniter was to be accomplished by any Calpine employee, including
the decedent. Additionally, it was
expected by Calpine management, that anyone, including the decedent, who may
decide to tackle the igniter replacement task, would first have to do a safety
assessment of the task, and in so doing, would have to readily see that the two
preconditions were not yet fully met as of the pre-dawn hours of December 22,
2010, and that it would be unsafe to access the upper platform, or its
surrounding zone of danger, due to the floor openings that were there.[134] Tarps were clearly still on top of the
combustion chambers and covered the place where the missing igniter was
located. (SF-14). The Court finds that the tarps on the
combustion chamber were readily visible from the ground level. The facts of this case make it unlikely that
the decedent would have found occasion to pass within ten feet of the floor
opening on the upper platform on December 22, 2010.[135] Here, there is no evidence that any Calpine
employee actually entered the zone of danger, the space within ten feet of the
floor opening at the north side of the west combustion chamber’s upper platform.[136] Nor was it predictable, or reasonably
expected, that any Calpine employee would have access to the floor opening on
the 17-foot upper platform, or the zone of danger, at the time of the accident.[137]
The
Court finds that the decedent never got within ten feet of the floor opening at
the north side of the west combustion chamber’s upper platform and that there
was no actual exposure to the hazard.[138] CO Weisenberger testified that she did not
know the location from which the decedent fell. CO Burgei acknowledged that his preliminary conclusion
that the decedent fell through an opening in the upper platform was not
supported by facts. AD Kulp also agreed
that OSHA had no evidence that the decedent was ever up on the upper platform
on December 22, 2010, and admitted that OSHA had no information proving that
the decedent actually fell from the upper platform. AD Kulp also testified that it was OSHA’s
position that the location from which the decedent fell to his death was
“inconclusive.” (Tr. 277-78, 895-96, 907-09, 1159, 1172). The Court finds that the uncontroverted and
un-rebutted testimony of Coroner Lysek and Forensic Pathologist Dr. Chmara
established that the decedent did not fall through the upper platform’s floor
opening. The Court finds their testimony
to be very creditable. Their
professional experience and credentials regarding their duties to determine a
decedent’s cause of death are impressive, even more so when weighed against
that of the two COs.[139] The Court observed the demeanor of Coroner
Lysek and Dr. Chmara during their courtroom testimony and found them both to be
honest, knowledgeable, impartial, professional, thorough, confident, direct,
and persuasive.
The
Commission has frequently found exposure through access where employees had
occasion to pass within 10 feet of an unguarded opening. See
e.g. A. Munder & Son, Inc. and Robert Catino, Inc., 4 BNA OSHC 1593,
1595 (No. 1858, 1976); Public Improvements,
Inc., 4 BNA OSHC 1864 (No. 1955, 1976).
The Court finds that the access ladder at “D”, RX-MM-I, that led to the
lower platform at “E”, RX-MM-I, was not more than five to seven feet in height
from the floor. The Court further finds
that the top of the un-caged portion of the ladder leading to the 17-foot
platform was not more than seven feet in height. The Court finds that there was more than ten
feet of distance from the point where the decedent fell in the area between the
ladders at “B” and “D”, RX-MM-I, to the floor opening in the upper platform,
which was 17 feet, 1 and 31/32 inches in height.[140] The Court further finds that the unguarded
upper platform opening was beyond the normal employee random movement
contemplated by the access test and that the unguarded floor opening was too
remote to pose a threat to the safety of the decedent on December 22, 2010. See Special Metals Corp., 9 BNA OSHC at
1134.
The
record shows that BEC had a multi-faceted safety program which included
training, audits, and discipline.
Several employees testified that safety training was required for all
employees on a monthly basis. Calpine
provided incentives, through monetary awards, to its employees for complying
with its safety training requirements. A
third party was hired in July of 2010 to conduct a safety audit and provide
additional safety training. Calpine had an
ongoing program in which employees evaluated each other for safety compliance. The testimony of two employees demonstrated
that assessing the safety requirements of a particular work activity was a part
of the work culture at the BEC facility.[141] Respondent’s Fall Protection policy called for supervisors, such as the
deceased, to “[p]erform a fall hazard assessment for each job and determine the
proper equipment and procedure for that specific task.” The Court finds that the evidence shows that
it is more probable than not that the decedent entered CT-6 with an igniter in
his pocket to perform an assessment of the job conditions related to the task
of installing the igniter into the east combustion chamber. [142] Whereas Mr. Lewis carried tools and an igniter
when he performed his safety assessment relating to the identical task the day
before, no tools were found with the decedent when his body was discovered
after the accident.[143] The Court finds that it was readily possible and
reasonably predictable for Calpine employees, including the decedent, to enter
CT-6 and perform a safety and readiness assessment of the igniter replacement
task without being exposed to the opening hazard at the upper platform more
than 17 feet above the floor.
Finally,
the record shows the decedent had a good reputation for safety, and there was no
evidence of his noncompliance in regard to safety. There is also no evidence in the record that
there was a general pattern of lax safety compliance by the BEC employees. No evidence was presented to show that the
decedent would be likely to engage in unsafe behavior.[144] The Court finds that, as a whole, Calpine had
a strong safety program and that the decedent’s general conduct was to follow
safety procedures. Calpine employees were trained to assess
their environments for safety prior to performing any work, to perform tasks
only in safe conditions, to use appropriate personal protective equipment (e.g. fall protection in any condition
such as that which existed at the time of the cited violation) when confronted
with an unsafe condition, or to not perform the assigned task. (Tr. 742, 998, 1800-04; GX-11).
The
information available to Calpine, when considered in its totality, shows that Calpine
would not have reasonably expected the decedent to be on the upper catwalk
platform when the opening was easily seen upon entering CT-6. No witnesses saw the deceased fall.[145] The
Court finds the Secretary has not shown it was reasonably predictable for the
decedent to be in the zone of danger.[146] The Court concludes, therefore, that the
Secretary has not proven either actual or reasonably predictable exposure to
the cited hazard.
The
Secretary cites to two Commission decisions to support her argument that the
task on the night order made it reasonably predictable that the decedent would
be in the zone of danger. Nuprecon LP, 23 BNA OSHC 1817, 1819 (No.
08-1307, 2012) petition denied, Order
at 1, No. 12-71026 (9th Cir. Jan. 17, 2013); Lancaster Enters., Inc., 19 BNA OSHC 1033, 1037 (No. 97-0771,
2000). The facts in both of these cases,
however, are distinguishable from the case at hand. In Lancaster,
employees actually used an access ladder that was “closely adjacent’ to an
unguarded skylight to gain access to their work area. In Nuprecon,
the evidence showed that an employee doing pipe removal work was “closely
adjacent” to an unprotected edge. Both
of these cases rely on evidence of actual exposure to the zone of danger and do
not aptly compare to the case at hand.
The
Secretary relies on two further Commission decisions to support her position
that it was reasonably predictable for the employee to be in the zone of danger. Pete
Miller, Inc., 19 BNA OSHC 1257, 1258 (No. 99-0947, 2000); Fabricated
Metal Prods., Inc., 18 BNA OSHC at 1074. In Fabricated
Metal, the Commission stated that “[I]n order for the Secretary to establish
employee exposure to a hazard she must show that it is reasonably predictable
either by operational necessity or otherwise (including inadvertence), that
employees have been, are, or will be in the zone of danger.”[147] Fabricated
Metal Prods., Inc., 18 BNA OSHC at 1074; see also Nuprecon LP, 23 BNA OSHC at 1817. The zone of danger “is determined by the
hazard presented by the violative condition, and is normally that area
surrounding the violative condition that presents the danger to employees which
the standard is intended to prevent.” RGM Constr. Co., 17 BNA OSHC 1229, 1234
(No. 91-2107, 1995); Seyforth Roofing Co., 16 BNA OSHC 2031, 2033 (No. 90-0086,
1994). The Secretary need only show employee
access to the zone of danger, and need not show that employees were actually
exposed. Donovan
v. Adams Steel Erection, 766 F.2d 804, 812 (3rd Cir. 1985). In addition, “[i]t is well settled that brief
exposures involved in passing or standing near an open edge constitute access.” Walker
Towing Corp., 14 BNA OSHC 2072, 2074 (No. 87-1359, 1991). Neither
Fabricated Metal nor Pete Miller assist the Secretary in her
position in this case. In Pete Miller, the CO observed an employee
handling materials close to the roof’s edge.
Here, there is no evidence that any Calpine employee walked on, passed
near or stood on the upper platform where the opening hazard was, or was within
ten feet of the opening at or before the accident. In Fabricated
Metal, the Commission found that the Secretary had not shown it was
reasonably predictable for an employee to be in the zone of danger, just as the
Court has done here.
The
Court finds that the Secretary has shown that the cited standard applies, that
the terms of the standard were violated, and that Calpine knew or could have
known of the hazardous condition.
However, as the Secretary did not prove the required element of actual
or reasonably predictable employee exposure, the citation is vacated.[148]
Findings of Fact and Conclusions of
Law
All findings of fact and conclusions
of law relevant and necessary to a determination of the contested issues have
been made above. See Fed. R. Civ.
P. 52(a). All proposed findings of fact
and conclusions of law inconsistent with this decision are denied.
ORDER
Based
upon the foregoing findings of fact and conclusions of law, it is ORDERED
that:
Item 1 of
Citation 1, alleging a serious violation of 29 C.F.R. § 1910.23(a)(7), is VACATED.
/s/
The
Honorable Dennis L. Phillips
U.S.
OSHRC Judge
Dated: May 22, 2013
Washington,
D.C.
[1] Subsequent to the issuance of the citation, OSHA promulgated
a revised final rule for fall protection in general industry. See
81 Fed. Reg. 82,494 (Nov. 18, 2016) (Walking-Working Surfaces and Personal
Protective Equipment (Fall Protection Systems)). Under the revised rule, there is no separate
requirement for “temporary” floor openings; in addition, the standard permits
the use of covers, travel restraint systems, or personal fall protection
instead of guardrails. 29 C.F.R.
§ 1910.28(b)(3)(i).
[2] Calpine’s night shift ran from 6:00 p.m. to 6:00
a.m. For each night shift, Calpine
assigned an LMO to serve as a supervisor and three operator maintenance
technicians to perform work.
[3] Although the platform contained a total of four
openings, the amended citation only alleges that an opening located close to
the west chamber’s access ladder was violative.
[4] Neither the coroner nor a forensic pathologist, both
of whom testified, could determine the precise location from which the decedent
fell, although both agreed it was not likely that he fell through an opening in
the upper platform. The pathologist
stated that he had not been asked to determine from where the decedent fell and
thus did not include it in his report.
However, after reviewing information provided by Calpine, he came to
believe that the decedent fell from somewhere near the ladder that led from the
ground floor to a lower platform.
[5] The standard defines a floor opening as “[a]n opening
[that] measures 12 inches or more in its least dimension in any floor, platform,
pavement, or yard through which persons may fall; such as a hatchway, stair or
ladder opening, pit, or large manhole.”
29 C.F.R. §§ 1910.23(a)(7), 1910.21(a)(2) (definition of floor
opening). The coroner estimated that the
cited opening was about 32 inches long on its right and left sides and that it
was sufficiently large for a person to fall through. Narkin testified that the
openings were not present under normal operating conditions, and it is
undisputed that they had been created during the overhaul project.
[6] Since the Secretary does not rely upon actual
exposure, the cause of the employee’s death—whether he fell through the cited
platform opening or from a ladder—is not relevant and need not be resolved by
the Commission. See Boeing Co., 5 BNA OSHC 2014, 2016 (No. 12879, 1977) (finding of
a violation does not depend on the cause of the particular accident that led to
the case); Concrete Constr. Corp., 4
BNA OSHC 1133, 1135 (No. 2490, 1976) (“The Act may be violated even though no
injuries have occurred, and even though a particular instance of noncompliance
was not the cause of injuries.”); Kansas
City Power & Light Co., 10 BNA OSHC 1417, 1422 (No. 76-5255, 1982)
(“Indeed, both the judge and Respondent improperly define the hazard at issue
in terms of the asserted cause of the specific incident that led to injury . .
. .”).
[7] In finding that exposure was not reasonably predictable, the judge relied on numerous factors that have no bearing on an exposure analysis. These factors include: (1) the low priority of the assigned replacement task; (2) the conditional nature of the authorization to do the task; (3) Calpine’s training of employees to conduct safety assessments; (4) the decedent’s good safety record; and (5) the obviousness of the hazard. The alleged low priority of the assigned task is irrelevant because it was included on the work order and employees were expected to complete the task during the shift for which it was first assigned, if time permitted. Any task not completed during a night shift would typically be rolled over to the next night shift’s work order until it was completed, which is what happened here with the assigned replacement task.
The remaining factors address the extent to which
Calpine was entitled to rely on its employees to comply with its instructions
and avoid engaging in violative conduct. However, such factors would relate to the
affirmative defense of unpreventable employee misconduct, but not to exposure. In any event, these factors are moot given
that, as discussed below, other considerations are dispositive of the
affirmative defense alleged by Calpine.
[8] There is no measurement of this distance in the
record.
[9] The record shows that some employees either knew or thought that the replacement spark rod was for the east chamber, but at least one did not. LMO William Varga stated that he knew the spark rod had been taken from the east chamber, but he did not know which burner. LMO Raymond Lutz testified that he was “pretty certain,” based on a conversation he had with the decedent, that it was the decedent who had removed the spark rod. Lutz identified the approximate location of where the spark rod was to be installed in the east chamber, but it is not clear how or when he learned of the location. Lewis testified, however, that he did not know where the spark rod needed to be installed; so, he would have had to walk around and look at each burner until he located the one with a spark rod missing.
[10] We disagree with the judge’s conclusion that this
case is distinguishable from Nuprecon
and Lancaster Enters. d/b/a Orbit Roofing,
19 BNA OSHC 1033, 1037 (No. 97-0771, 2000).
He read those cases as involving employees who had actually entered the
zone of danger, but in fact the Commission found only that it was reasonably foreseeable the employees in
both cases would enter the zone of danger; not that they actually did. See
Nuprecon, 23 BNA OSHC at 1820 (finding it reasonably predictable that an
employee on a lift would dismount the lift and work in the zone of danger); Lancaster, 19 BNA OSHC at 1037 (“The use
of the hatchway to get to and from the roof made it reasonably predictable that
an employee would enter the zone of danger presented by the unguarded glass
skylight.”). Similarly, Calpine assigned
a task to its employees that would have brought any one of them immediately
adjacent to an unguarded opening. That a
Calpine employee was not shown to have actually entered the zone of danger does
not alter the fact that it was reasonably predictable, by virtue of the
assigned task, that an employee would have entered the zone of danger to
complete the task. See Pete Miller, Inc., 19 BNA OSHC 1257, 1258 (No. 99-947, 2000)
(even if employee “never [got] closer than eight feet from the edge” of a roof,
it was reasonably foreseeable that he would enter danger zone due to nature of
work).
[11] Calpine does not challenge the judge’s finding that
these five individuals were supervisors.
See Diamond Installations, Inc.,
21 BNA OSHC 1688, 1690 (No. 02-2080, 2006) (supervisory status turns on the
delegation of authority, not the title of the employee); Jersey Steel Erectors, 16 BNA OSHC 1162, 1164 (No. 90-1307, 1993)
(knowledge of a foreman or supervisor can be imputed), aff’d, 19 F.3d 643 (3d Cir. 1994).
Nor does Calpine dispute the judge’s decision to treat Killgore and Rice—engineers
employed by a Calpine affiliate that the judge found operated as a single
entity with Calpine—as Calpine employees.
[12] We note that Calpine also raised the affirmative
defense of infeasibility in its answer but did not argue the defense before the
judge and did not raise it on review. As
a result, the Secretary claims that Calpine has abandoned the defense. Regardless of whether Calpine has preserved this
claim, we find that the defense fails. To
prove infeasibility, an employer must show that: (1) literal compliance with
the terms of the cited standard was infeasible; and (2) an alternative
protective measure was used or there was no feasible alternative measure. Otis
Elevator Co., 24 BNA OSHC 1081, 1087 (No. 09-1278, 2013), aff’d, 762 F.3d 116 (D.C. Cir.
2014). Here, Calpine claims that “there
is no evidence in the record that there existed a method to install guardrails”
and that a “constant attendant would not protect the person reaching through
the floor opening to perform tasks involved in rebuilding the combustion unit
and catwalk.” As Calpine has the burden of proving infeasibility, the absence
of evidence regarding these claims means Calpine has failed to establish the defense’s
first element—that literal compliance with the cited requirement could not be
achieved.
[13] Calpine requests that if the Commission reverses the judge on the issue of exposure, its UEM defense be remanded to the judge for consideration. We decline to remand, as Calpine’s defense raises a legal issue that is appropriate for the Commission to resolve. See Power Sys. Div. United Techs. Corp., 9 BNA OSHC 1813, 1813 n.5 (No. 79-1552, 1981) (question of law does not require remand).
[14] On review, the parties do not challenge the
characterization or proposed penalty, and we find no reason to depart from the
characterization alleged and the penalty proposed in the citation. E.g.,
KS Energy Servs., Inc., 22 BNA OSHC
1261, 1268 n.11 (No. 06-1416, 2008) (affirming alleged characterization and
assessing proposed penalty when characterization and penalty are not in
dispute).
[15] A
recommended draft citation for an alleged violation of 29 C.F.R. § 1926.501(b)(4)(i)
for exposing the deceased to an un-guarding temporary floor opening that
Siemens created at CT-6 on December 22, 2010 was not approved for issuance to
Siemens by OSHA. (Tr. 427-29, 1219-22;
RX-J). Area Director (“AD”) Jean Kulp
testified that to her knowledge Siemens’ employees wore fall protection when
working at elevated levels when openings in the catwalk existed. She also testified that Siemens’ employees
not working at elevated levels while catwalk openings existed did not wear any
fall protection. She further testified
that Siemens’ employees at CT-6’s ground level had ladder access to the upper
[catwalk] levels when there were openings that did not have any physical
barriers or attendants guarding them. OSHA
did not issue a citation to Siemens relating to its activities at BEC. AD Kulp also testified that OSHA did not cite
Calpine for any activity that occurred at CT-6 during the overhaul before
December 22, 2010, including when Mr. Lewis entered the ground floor of CT-6 on
December 21, 2010 at a time when there were openings in the catwalk that were
not guarded by guardrails or attendants.
(Tr. 1222-23, 1227-34).
[16] Calpine’s 19 affirmative defenses
are summarized as follows: (1) another
entity had control over and caused the hazardous condition; (2) it was neither
feasible nor was it required for Calpine to implement the requirements of the
cited standard; (3) OSHA’s forms, information, exhibits and complaint contain
false, inaccurate, and misleading information; (4) Calpine follows all
reasonable and acceptable workplace standards and guidelines including OSHA
standards; (5) Calpine took reasonable steps to ensure that Siemens was aware
of its obligation to follow safety standards; (6) Calpine took all reasonable
steps to keep its employees away from CT-6 while it was under Siemens’ direction
and control; and (7) the alleged violation was the result of unpreventable
employee misconduct.
[17]
The stipulated facts (“SF”) were read into the hearing record and at that time
minor changes were made to Stipulated Facts 10, 11, and 13; both parties agreed
to these changes. (Tr. 16-23).
[18]
In the interest of privacy, the name of the deceased employee has been omitted
from the decision.
[19]
CT-6 [also sometimes referred to as “Unit 6”] refers to the building housing
Combustion Turbine 6. (Tr. 493-94, 696; RX-MM). CT-6’s walls are depicted in a rectangular
shape highlighted in yellow on exhibit RX-MM-E by Mr. Timothy Lewis. (Tr. 641; RX-MM).
[21]
Mr. Miller has a Bachelor of Science degree in mechanical engineering from
Virginia Polytechnic Institute and State University (“Virginia Tech”). (Tr. 1532).
[22]
Mr. Narkin described the 17 OMTs/LMOs as being a very skilled workforce, all
with a least two year technical degrees, and almost all with experience working
at BEC for about eight years. (Tr.
1447).
[23]
This was an “acting” position for the LMOs from July 2010 to February 2011; at
that time it was changed to an official position. (Tr. 439-40, 512). In May, 2012, Mr. Lutz testified that about
28 Calpine employees worked at the BEC facility. CO Weisenberger testified that she was told
that Messrs. Lutz and Roy Killgore monitored Siemens’ work at the BEC
facility. (Tr. 420-21, 443).
[24]
Mr. Lutz, an LMO who started working at BEC in 2002, testified that prior to
Calpine’s purchase of the BEC facility in July 2010, there was a
shift supervisor for each shift; however, that position was eliminated with the
Calpine purchase. (Tr. 441-42). Mr.
Lewis testified that one member of the crew runs the control room, two members
are each assigned to power block 1 or 2, and the fourth crew member is the
floating operator who assists the other operators. (Tr. 681-82, 1440-41).
[25]
LMO Varga testified that he was responsible for the day-to-day operations
during his shift. (Tr. 694). LMO Lewis testified that he considered
himself to be the OMTs’ supervisor because there was no other management on site
during the night shift. (Tr. 603).
[26] Mr. Narkin testified that the night
shift’s LMO has greater responsibility because management is not on site during
the night shift. (Tr. 1446-47).
[27]
The Master Agreement that governed the overhaul effort called for Siemens to
direct its employees and comply with the Act.
(Tr. 1362-68; RX-N).
[28]
As part of the overhaul, Siemens removed CT-6’s roof panels, moved the two combustion
chambers out three inches, removed at least part of the catwalks thereon, and lifted
the turbine rotor identified at RX-MM-H at “A” from the building to be worked
on elsewhere. Mr. Killgore testified
that when the center case and rotor were removed, Siemens placed caution tape
on top of the combustion chambers’ platform indicating that those areas were
open. During that time, some of the
platforms were in place and some were removed, including those over the center
line of the turbine unit. Siemens
barricaded off the platform ends that led to the center line. After finishing its work on the turbine rotor,
Siemens had replaced the rotor, roof panels, and most of the catwalk by the
time of the accident. The missing
platform grates were to be reinstalled by Siemens during the December 22,
2010’s day shift, after 6:00 a.m. (Tr.
337, 357-61, 955-59, 1401; JX-III, at p. 2, JX-XIV, at p. 11, GX-7, at p. 2, RX-J,
at p. 2, RX-MM-H, at “A”).
[29] Mr.
Narkin testified that CT-6’s combustion turbine was undergoing a modified,
major overhaul that did not require the two combustion chambers to be removed
from the building. The modified, major
overhaul did require the removal of at least a portion of the platforms that
surrounded the two combustion chambers. Mr.
Varga also testified that Siemens controlled that area during the overhaul
outage. He further stated that although
he generally stayed away from the area, it “wasn’t unheard of to stand at a
safe distance and observe for a little while - - ….” He agreed that he told his crew to stay away
from the area because of the inherent dangers there. He testified that he told his crew that if
they did not need to be in the area they should not be there. He also agreed that he would not have sent
either himself or any members of his crew to the CT-6 catwalk when there were
platform openings to install a spark rod.
(Tr. 733-34, 742-43, 1000-01, 1376).
[30] Mr.
Killgore testified that he has a Bachelor of Science degree in engineering and
that he worked at BEC from October 18, 2010 through December, 2010. He testified that he considered himself
“management,” but not really a supervisor. He was the Plant Manager at the Hay Road
facility in Wilmington, Delaware from 2000 through July 1, 2010 that had the
same Siemens’ model number turbines that existed at BEC. Mr. Rice testified that he worked at BEC from
December 10 through 2:00 a.m., December 22, 2010. (Tr.
940, 945, 1069, 1075, 1360-61, 1375, 1391; RX-P, at p. 5).
[31]
The OPSA indicated that a major inspection of a Siemens’ model V84.2 combustion
turbine extended through 33 calendar days.
Siemens started its turbine overhaul effort at BEC on October 18,
2010. Siemens began overhauling CT-6’s
turbine right after Thanksgiving, 2010; i.e.
after November 25, 2010. (Tr. 1391, RX-P,
at p. 40).
[32]
Mr. Rice testified that it was customary for Siemens to not send a copy of its
shift turnover reports to Calpine’s control room. (Tr. 981-82).
Mr. Rice testified that he saw Siemens’ day to night shift Shift
Turnover Report for December 21, 2010 at about 5:00 p.m., December 21,
2010. That report stated that Siemens
had “Hot bolted platforms and catwalks” earlier that day and indicated that
additional work was scheduled to “Torque platforms – double nut as necessary
for looseness”. (GX-7 at p. 1). Mr. Killgore testified that he received a
paper copy of Siemens day shift Shift Turnover Report at 5:00 p.m. each
day. (Tr. 1379; GX-7).
[33]
Mr. Killgore testified that “hot bolt platforms and catwalks” meant the bolts
were not fully tightened to torque specifications after the platform grates had
been lowered into place. (Tr. 1081-82;
GX-7, GX-9).
[34]
Mr. Rice testified that the Siemens’ night shift personnel did not work on the
upper catwalks during that time frame. (Tr. 978, 983-84; GX-7).
[35]
AD Kulp testified that she imputed knowledge of the unguarded catwalk openings
to Calpine based upon information contained in Siemens’ reports. Using the sender address roy.killgore@calpine.com, Mr.
Killgore sent TMG’s daily status report for December 21, 2010 that reported
that Siemens’ December 20, 2010 day shift had “Hot bolted platforms and
catwalks” to Mr. Miller and others by email at December 22, 2010, 7:48 a.m., a
few hours after the accident. Mr. Rice,
however, had seen Siemens’ Shift Turnover Report for December 21, 2010, at 5:00
p.m., December 21, 2010, many hours before the accident and Mr. Killgore had
firsthand knowledge of the platform openings by 5:00 p.m., December 21,
2010. (Tr. 1284; GX-6, at p. 1,
GX-9).
[36]
The Calpine TMG Daily Shift Turnover Report reported that eleven Siemens
personnel worked during the December 20, 2010 night shift at CT-6. (Tr. 1021; GX-8).
[37]
AD Kulp confirmed that the report showing the work Siemens completed on its
12/21 night shift would not have been distributed until later in the morning on
12/22, after the fatality accident occurred.
(Tr. 1283-84, 1290; GX-7, at p.1).
[38]
Mr. Killgore testified that Calpine BEC employees could enter and work in
CT-6’s northern half, where a heat exchanger, generator, exciter and oil tank
were located. This area was beyond the
area in CT-6’s southern half where Siemens was performing work related to the
turbine overhaul. (Tr. 1385; RX-MM-I). He further testified that Siemens posted at
CT-6’s doors or around the turbine a Foreign Material Exclusion (“FME”) sign
that required personnel entering the turbine’s centerline area to record
material, such as tools, including wrenches and sockets, and pens, that entered
and exited the designated area. Mr.
Killgore agreed that the FME sign did not restrict access to the entire CT-6
building. (Tr. 1387-88, 1426).
[39]
Mr. Miller testified that he considered igniter installation to be a task that
allowed a Calpine employee to enter a building, such as CT-2, at a time when
Siemens was performing a major overhaul.
(Tr. 1019).
[40] Mr. McClelland has been an
instrumentation and electrical technician at the BEC facility for approximately
ten years. (Tr. 1795).
[41]
Mr. Narkin testified that neither he nor Calpine employees needed to wear any
fall protection equipment when walking on the catwalks when all the grates were
in place because the engineered fall protection, including railings, was in
place. (Tr. 1014, 1513).
[42] Mr.
Lutz testified that Calpine provided a crane operator to Siemens to work in
CT-6 during the overhaul. Mr. Lutz
further testified that he was never given any task that required him to go onto
the platform surrounding CT-6’s combustion chamber. The Court finds that Mr. Lutz was referring to
the time frame while Siemens’ personnel were working in CT-6. He was instructed by Calpine management not
to work in areas where Siemens was working. (Tr. 451, 454-55, 530, 1478). He further testified that he had been on the
[17-foot] platform at other times. When
up on the platform, Mr. Lutz believed that there was no need for fall
protection because there were railings, kick boards, and cages around the
ladders. He also testified that before
the accident he was never trained to wear fall protection when going onto the
platforms. (Tr. 451-52). LMO Lewis denied that he had been directed
not to work in the area where Siemens’ personnel were working; but he
acknowledged that he stayed away from the area of CT-6’s two combustion
chambers when Siemen’s was performing work there. He also did not allow his crew to be there,
unless they had a purpose for being there.
He testified that he and two other employees, Messrs. Greg Kulanko and
Bill Vargas, had been instructed by Mr. Narkin to enter CT-5 to hook up an oil
filtration system while Siemens’ personnel were working in the area sometime
after 2010. (Tr. 589-91, 635, 641-46;
RX-MM-E). LMO Varga testified that he
was unaware before the accident of any instructions to Calpine employees to not
work in areas where Siemens’ personnel were working. He recalled entering such an area to cover up
auxiliary equipment with plastic since the roof was removed and a Calpine
operator regularly operated a crane there.
(Tr. 704-05, 733). Mr. Rice
identified the crane operator as Lee.
(Tr. 937-38). Mr. Narkin
testified that if Siemens wanted to get a Calpine employee to perform a task in
CT-6 during the overhaul effort, Siemens would seek to do so through Messrs.
Killgore, Rice, Miller, or himself. (Tr.
1477-79).
[43]
Mr. Lewis holds Bachelor of Arts degrees in mechanical sciences, political
science, and sociology. (Tr. 671).
[44]
A spark rod is an igniter used to ignite a combustion chamber. The spark rod is also referred to as a spark
rod cap, spark plug, igniter tip, igniter, or an igniter rod in the record. Mr. Lutz further testified that the deceased
had removed a spark rod cap from CT-6 and installed it in Building CT-2 as
directed by the December 17, 2010 Weekend Order. On about February 17, 2011, a Calpine employee
told Compliance Officer (“CO”) Weisenberger that “Bob” [Itterly] had worked on
igniters with the deceased a week before the accident and that they had taken
parts from CT-6 to use in CT-2. (Tr. 172,
458-59, 701-02, 997-98; JX-XIV, at p. 6, GX-10; RX-MM-B, D and F). Mr. Miller testified that the deceased was
involved in replacing an igniter at CT-2 on about December 15, 2010. (Tr. 1560-61; GX-15).
[45]
Mr. Lutz testified that installing a spark rod was “a matter of screwing a
little tip onto a threaded piece.” He
further testified that you could “flop it [the tarp] up” to access the place
for the spark plug on top of the east combustion chamber in CT-6 since the
place was close to the edge. (Tr. 468, 496-97;
RX-MM). Mr. Lutz also testified that the
deceased removed the spark plug from the south eastern side of the east
combustion chamber. (Tr. 497; RX-MM-B, at “D”).
Mr. Varga also testified that although he believed a spark plug needed
to be replaced at the east combustion chamber, he did not know precisely which
spark plug needed to be replaced. He
also testified that he did not know if there were missing grates where the
spark plug needed replacement. He also
stated that there was “no sense of urgency” on December 22, 2010 to replace the
missing spark plug because the CT-6 turbine was not going to be placed back in
operation until after the Christmas holidays.
Calpine’s December 20, 2010 night order stated that CT-6 “will probably
be test run on 12/30.” (Tr. 712-13,
738-40, 1403; GX-5). Mr. Lewis also testified the tarps would not have
prevented him from replacing the missing spark plug because the tarp was
bungee-corded to the chamber’s top. He
stated that he could have pulled up on the bungee cord, peeled back the tarp
and gained access to the combustor burners where spark plugs were used. He
also testified that he would have worn fall protection if he had replaced the
spark plug located at the south east side of the east combustion chamber on
December 21, 2010. Mr. Lewis also
testified that he observed Siemens’ personnel wearing fall protection when he
occasionally entered CT-6. (Tr. 580-81,
678-80, 689-90). A Contractor Job
Safety Audit performed by Mr. Ed Rodichok, an employee of TekSolv, at 10:30
a.m., December 21, 2010, rated Siemens’ use of fall protection as satisfactory
while performing an assembling task at CT-6.
(Tr. 1022-25, 1555, 1575-77; RX-LL, at pp. CALPINE002031-2). Mr.
Killgore testified that he watched the crane lower the platforms in place in
CT-6 on December 21, 2010 and saw Siemens’ workers wearing fall protection
harnesses on the platforms. He further
testified that some Siemens personnel did not tie off properly, some Siemens
workers hooked onto guardrails or handrails, while others did not. He did not know whether the Siemens safety
representative, who was also present, said anything to the improperly tied off
Siemens employees, although Mr. Killgore stated the safety representative
should have. (Tr. 1396-97). Mr. Killgore stated that he did not see any
Calpine workers on the platform area during the December 21, 2010 day shift. He further testified that while in CT-6 during
the December 21, 2010 day shift, he could see from ground level that tarps were
still covering both combustion chambers, including igniter locations. He also testified that he saw from the ground
level that the combustion chamber platforms had been hot bolted and there were
platform openings where grates were left up against the handrail or on top of
other grates where Siemens had to later formally tighten the platforms to
torque specifications. (Tr. 1397-99,
1401-02).
[46] Mr.
Lewis had replaced combustion chamber spark plugs before. Mr. Lewis testified that there were six
combustors that used spark plugs in each of the two combustion chambers and he
would have needed to check each one to determine which of the twelve combustor
sites was missing a spark plug. The
spark plugs were located in all directions around the combustion chamber’s
circumference. Mr. Varga testified that
the spark plugs were about three feet apart. (Tr. 578, 666, 743). Mr. Narkin testified that replacing the spark
plug at CT-6 was “a very fast job. It
should only take a couple of minutes to do it.”
(Tr. 1485).
[47] Mr.
Lewis testified that he started his trip to CT-6 from either the control room
or maintenance shop, both located west of CT-6.
He then headed to the HRSG Building because it was very cold, near zero
degrees, outside and entered CT-6 through its southern doorway, less than 50
feet from the HRSG building, which put him at the ground floor where there was
an access ladder leading to the catwalks.
The roof was still off CT-6. Mr.
Lewis also testified that during the early morning of December 21, 2010 it was
harder to see inside CT-6 because the roof was not installed and not all of the
lights were on. He was, however, able to
see the grate opening and tarps surrounding the combustion chambers. He did not know whether or not there were any
grate openings at the northern side of the two combustion chambers. He also did not know how far the tarps draped
down, or how difficult it would be to install the spark plug, on the combustion
chambers’ northern side. Mr. Lewis
testified that he thought it would be impractical to carry tools and the spark
rod and enter CT-6’s west door because to then get to the combustion chamber
one needed to either go down a vertical ladder or circle around to CT-6’s east
side. When he returned from CT-6, he
returned the tools to the maintenance shop and put the uninstalled spark plug
on the control room’s counter. (Tr. 571,
573-74, 581-82, 654-55, 657-70; RX-MM-E).
LMO Varga also testified that coming from the control room he would have
entered CT-6’s southern door to access its combustion chambers from the ground
level. (Tr. 702-03, 745). AD Kulp admitted that OSHA was unable to
determine the actual path the deceased took within CT-6, or through which door
he entered the building. She also agreed
that the she had information that there was a possibility that the deceased had
entered CT-6 to merely assess the job area.
On February 17, 2011, a Calpine employee told CO Weisenberger that the
deceased “didn’t have tool belt – Think was accessing job area.” AD Kulp also testified that OSHA did not know
what activity the deceased actually did within CT-6 during the morning of
December 22, 2010. She testified
“Whether or not he [the deceased] went there [into CT-6] to assess or perform
work we don’t know for sure.” (Tr.
1293-94, 1297, 1303, 1305-06; JX-XIV, at p. 3).
[48]
Mr. Lewis testified that the catwalk’s deck plates were “a few feet wide” and
anywhere from a foot to several feet long.
He identified where he saw catwalk deck plates missing in the southeast
quadrant of the west combustion chamber opposite the caged access ladder, as
well as the area connecting the two combustion chambers. Mr. Lewis also testified that on December 21,
2010 he saw a grate plate missing from combustion chamber six [the west
combustion chamber of CT-6] that he identified at photograph GX-1, at “B”
[shown with yellow tape hanging down]. Mr.
Lewis did not see any yellow, safety “barricade” tape hanging down from the catwalk’s
railing at that location on December 21, 2010. (Tr.
575-80, 584-85; RX-MM-C and D).
[49]
Mr. Lutz testified that he was “pretty certain” that during the morning of December
21, 2010 he discussed Mr. Lewis’ safety concerns with the three other members
of his crew, including perhaps Ronnie Frank and Greg Sinsky. Mr. Lutz did not instruct his second,
possibly Mr. Frank, to advise the deceased of Mr. Lewis’ safety concerns. (Tr. 536-37, 541-43, 546-47, 673).
[50]
Mr. Lewis testified:
Q. Who if anyone did you inform – about your
decision not to replace the spark rod?
A. I told the oncoming LMO Ray Lutz
Q. Anyone else?
A. Tom Narkin was in the room and I told him.
Q. Okay.
Did you tell Mr. Narkin why you did not replace the spark rod?
A. I said – I told Ray that during the turnover
and Tom it wasn’t safe to do.
Q. Did you explain why it wasn’t safe?
A. Because the decking was missing.
(Tr. 581).
[51]
Mr. Lutz testified that Mr. Lewis told him that he was unable to replace the
spark plug because there was a lot of missing equipment, grading and other
things, and he did not feel safe going up onto the platform. (Tr. 462-63).
[52]
CO Weisenberger testified that Mr. Narkin told her on December 22, 2010 that a
work order instructed the deceased to replace a big spark plug. (Tr. 331-32; JX-XIV, at p. 9). CO Burgei testified that the Calpine
officials he and CO Weisenberger spoke with on the morning of December 22, 2010
“did not know what he [deceased] was doing in the area. They told us they weren’t sure of what he was
supposed to be doing or why he was there.”
CO Burgei’s December 22, 2010, 12:59 p.m. email to CO Weisenberger
stated that “Allegedly no one knew why he [deceased] was up there, or if he was
supposed to be up there or why he didn[]t (sic) replace the flooring.” (Tr. 907-08, RX-D). Police Officer Christopher Kopp’s Incident
Report stated that Mr. Narkin told him on December 22, 2010 that the deceased
“had email (sic) Narkin at 0215 hours and then was to complete a work order to
replace the spark rod in the combustion chamber.” Mr. Narkin also reportedly told Officer Kopp
that “If the grates were removed, by company policy there should have been
yellow tape and/or a plywood barricade across the danger area denying access.” Chief
Deputy Coroner Coy Smith stated in the Coroner’s Investigation Report that Mr.
Narkin told him on December 22, 2010 that the decedent “had sent an email to
another employee at 2:15 a.m.” Officer
Kopp stated in his Incident Report that he [Officer Kopp] believed that the
deceased “fell headfirst through the open grate.” In early 2011, a Siemens’ employee told CO
Weisenberger that a “spot light was shining where [the] ‘spark plug’ goes [sic].” CO
Weisenberger testified that she was told that the deceased had a spark plug in
his pocket when found on the floor. (Tr.
384, 1293; JX-XV, at p. 4, RX-L, at p. 5, RX-M).
[53]
This limiting instruction was not included in the night order given to Mr.
Lewis on December 20, 2010. (Tr. 588).
[54] Mr.
Lutz testified that he had seen the 12/21 night order earlier that day. Its last listed task was, “If tarps and
Siemens are not in the way install new spark rods in the control room counter
in CT-6, where one was borrowed from C[T]-2 this past weekend.” (Tr. 464; JX-XIII). Mr. Lutz interpreted that to mean that if
“the tarps were not preventing the job from being done and Siemens left that
evening that would be when they weren’t under their feet trying to work around
them.” He also testified that no one in
management had instructed him how to interpret the phrase, “if tarps and
Siemens are not in the way.” (Tr. 467).
[55]
This discussion generally occurred in the control room, which is in a building
just to the west of CT-6. (Tr. 498, 536).
[56]
At the hearing, Messrs. Lewis, Lutz and Narkin all testified that they had not
told the decedent about the openings in the platform. (Tr. 1007, 1011).
[57]
LMO Varga testified that Siemens’ personnel worked two 10 hour shifts and were
offsite between 3:30 a.m. and 7:30 a.m.
(Tr. 706).
[58]
The December 21-22, 2010 night shift crew included the deceased and Messrs. Joe
Brey, Greg Boardman, Bob Itterly and John Horvath. (Tr. 484-85).
[59]
The Coroner’s Investigation report stated that the body was about 25 feet
inside from CT-6’s main entrance. (RX-L,
at p. 4).
[60]
There was also a separate ladder leading up to the northeast part of CT-6’s
east combustion chamber. Both ladders leading to the 17-foot platforms of the
west and east combustion chambers were cage protected. There was a swing metal gate at the top of
the 17-foot ladder that reached the west combustion chamber’s catwalk. CO Burgei testified that when looking at the
gate, the gate swung to the left. (Tr.
774, 779-80, 850; GX-1, at p. 11, GX-16, at 1, GX-17B, RX-MM). Mr. Lutz testified that he thought it was
quicker, with no flight of stairs involved, to proceed from CT-6’s southern
entrance to the east combustion chamber by using the access ladder to the west
combustion chamber. He also acknowledged
that there were two doors on CT-6’s north and west side that were closer to the
maintenance shop. (Tr. 497, 501-03;
RX-MM). He also testified that one
could walk a couple of strides from the CT-6 west side entry way door and reach
a “little ladder” with a swing gate at the top that led to the Inlet Guide Vane
(“IGV”) platform, which was surrounded by a waist-high railing. (Tr. 552-53, 556; RX-MM, at “G”). Mr. Lutz also testified that one could enter
either the north or west door to CT-6, hop a railing, and climb atop a particle
board and then gain access to the IGV platform, as an alternative to climbing
the five or six-foot ladder. (Tr.
558-60; JX-XXXIV, at p. 6). Mr. Lewis
also testified that CT-6’s north door was close to the parking lot west of
CT-6. (Tr. 659-60; RX-MM-E).
[61]
Mr. Lutz testified although CT-6 was typically well lit, at about 5:30 a.m.,
December 22, 2010, it was kind of shadowy and “kind of dark” in the area where
the deceased was because Siemens had re-installed the roof several hours before
and the lights nearest the deceased had not yet been reconnected. He stated that it was “Not dark like oh, I
can’t see nothing, but shadowy.” (Tr.
491-92, 742). CO Burgei also testified
that he could see the catwalk’s condition before climbing the access
ladder. (Tr. 843).
[62]
Mr. Varga testified that neither he nor any of the other operators had been up
on the catwalk platform when there were holes in the platform. (Tr. 731-32).
[63] Mr.
Varga testified that he saw a grate opening slightly east of the access ladder
leading to the west combustion chamber.
(Tr. 699-700; RX-MM-F, at “A”, RX-MM-G, at “A”). Mr. Varga identified the approximate
locations of four holes in each of the upper platforms surrounding the two
combustion chambers in CT-6. Mr. Lutz
also testified that a platform opening was above where he found the
deceased. (Tr. 492, 710-11, 1014;
RX-MM-G).
[64]
Zachary R. Lysek has been the Northhampton County coroner since 1992. Since then he has been involved in or
supervised the investigation of 21,000 deaths.
This includes about 620 cases attributed to accidental death, as opposed
to suicide, homicide, or natural death.
Of the accidental deaths, 36 were workplace related. Prior to being coroner, he investigated
accidents and all types of crime scenes as a policeman for about 8 years. He has worked in the trauma room and pathology
department as a forensic pathology assistant at the Lehigh Valley
Hospital. He also worked full-time as a
forensic pathology assistant involved in autopsy and forensic investigations
with a group of forensic pathologists. He
was a medical investigator in Warren County, New Jersey and served as
Northhampton County’s deputy coroner for about four or five years before being
appointed coroner. Since 1992, he has continued his training, which has included
classes in accident reconstruction, crime scene investigation, and blood
pattern analysis. He has two bachelor
degrees in management and administration and safety management from DeSales
University. He testified that his job is
to “investigate death to determine the cause and the manner of death, to
determine what happened to an individual, how it could have happened and
whether or not this could potentially – the death could have occurred as a
result of someone’s else’s action.” (Tr.
1580-86, 1708).
[65]
Coroner Lysek testified that the Bethlehem Police 911 center was contacted at
about 5:42 a.m., December 22, 2010. Once
the police determined at the scene that the individual was dead, police officer
Kopp contacted the coroner’s office at 6:07 a.m. (Tr. 1633-34, 1674; RX-L, at p. 3).
[66]
Coroner Lysek testified that he assumed that the decedent entered CT-6 through
its west door as was commonly done. (Tr.
1594).
[67]
Coroner Lysek testified: “Your Honor,
the gloves that [the decedent] was wearing was a pair of brown bronze colored
cotton work gloves. They were on his
hands properly, his fingers were in each of the finger holes properly. I paid close attention to that because at the
scene, one of the questions I had was could he have grabbed a hold of anything
in an attempt to stop his fall or prevent his fall. And the gloves were loose fitting, they would
have - if he would have grabbed hold of something they would have moved off his
hand, and the hand - they were not off his hands, but they were properly on
each of his hands, both and his right and his left hand, sir.” (Tr. 1650, 1671; JX-XVI at CALPINE000077).
[68]
He identified the lower platform at RX-MM-I at “E”. (Tr. 1601-02).
[69]
Coroner Lysek testified that from the concrete floor he could clearly see the
holes in the upper platform catwalk and they were obvious when he entered
CT-6. (Tr. 1607).
[70]
He testified that he had to step on the lower of two railings and then put his
leg over the top railing and then put it back on the lower railing to get
down. (Tr. 1714).
[71]
Coroner Lysek testified that he chose to walk using the I-beams that were below
the particle board to avoid walking across only the particle board because he
was not very light. He testified that
“it probably wasn’t the smartest or the safest way to move” between the lower
platforms at “H” and “E”. He found the
particle board area to be “a dangerous area to walk.” (Tr. 1610-11, 1632-33; JX-XXXIV, at p. 6, RX-MM-I). He further testified that the upper platform
opening at “I” could not have played any role in the accident because it was on
the opposite, south side of the west combustion chamber in CT-6. (Tr. 1616; RX-MM-I).
[72]
Coroner Lysek described the opening as a slice of pizza pie with the tip of it
being cut off. He estimated both opening
sides to be about 32 inches, decreased by a 1.5 to 2 inch lip that the missing
grate would sit on, with a beam about 1.5 to 2 inches beneath the opening’s
east side. He also estimated the
opening’s outside radius to be 22 inches and the inner radius to be about 15
inches. He saw “a lot of sharp edges or
angles of metal” there, including two bolts.
The north side of the opening was wider because it was the outer curve
of the upper platform. He estimated that
the height of the railings at the upper and lower platforms to be about three
to four feet above the platform floors.
(Tr. 1615-18, 1629-32, 1716-17; JX-XXXIV).
[73] Coroner Lysek testified that he looked for
tissue, blood, and clothing fibers to indicate where the decedent could have
been standing when he fell; he looked carefully at the opening in the 17-foot-high
catwalk for any tissue, blood, material, fiber from the decedent's clothing, or
a swipe in the dust. He found no
physical evidence on the opening. He
paid close attention to this area because the law enforcement officers
initially focused on the upper platform floor holes as a potential area where
the decedent could have fallen through. (Tr. 915-16, 1612-15, 1645-47; RX-L. at p. 4).
[74]
“[B]ecause of the size of the opening in the upper catwalk, which ultimately
was not really that big, [the deceased] was 5 foot 11, about 200 pounds, you -
if a person were to trip on that upper catwalk they would have had to have gone
through that hole on the upper catwalk at an angle. The only way to do that is to impact with the
metal surfaces, which would have caused some form of injury. . . . where the
body was with respect to where the opening was it was a distance over - I would
estimate approximately four feet north of the opening in the floor, and I don't
think that he could have - where he fell - when people fall they don't fall at
angles, they fall straight down . . . . and with that fact and where he fell he
did not move.” (Tr. 1683-85; RX-L, at
p.2). The autopsy reported the
decedent’s height at 70 inches and weight at 219.5 pounds. (Tr. 1747; RX-L, at p. 9).
[75]
Coroner Lysek testified that the fixture that his office initially retained as
evidence could also be described as the silver tip that unscrews from the top
of a spark plug. (Tr. 1722).
[76]
The Coroner’s Investigation Report stated how the injury occurred as “Fell from
catwalk.” (RX-L, at p. 2).
[77]
Coroner Lysek testified that the ladder at “D” was within inches of the
decedent’s head. (Tr. 1732).
[78]
Coroner Lysek testified that there were about seven steps before the safety
cage surrounded the ladder leading to the upper platform. (Tr. 1612-13).
[79]
CO Weisenberger, a safety specialist, was the lead investigator; she became a
CO at OSHA’s Allentown office in 2004. Before
that, she served as an OSHA system administrator subsequent to 1991. By December 2010, she had conducted about five
inspections that involved falls, including one that involved a fatality in 2006
where an employee fell from a roof. Mr.
Burgei, an industrial hygienist, became a CO in the same office in April
2010. CO Burgei was there to “mostly
just kind of observe”, assist in the inspection, and for training purposes. He testified that he had no involvement with
the inspection after December 22, 2010 until he was alerted that he was going
to be deposed. He was deposed on
February 21, 2012. He did, however,
discuss the case with OSHA personnel on and after December 22, 2010 through
June 14, 2011, and he obtained the coroner’s report on February 17, 2012, which
he delivered to the OSHA area office on February 22, 2012. (Tr. 124-25, 181-82, 193, 205, 224, 432-33, 766-69,
801-03, 808, 811-14, 837-39, 846-47, 890-93, 1049, 1185-86).
[80]
CO Burgei testified that CT-6’s lighting was sufficient for him to conduct his
investigation. (Tr. 894).
[81]
CO Weisenberger testified that Mr. Narkin told her that the decedent had fallen
through the opening in the platform.
(Tr. 157-58, 639; RX-MM-1 also marked as RX-MM-A).
[82]
CO Weisenberger testified that the coroner told her that blood by the drain had
been cleaned up at the accident site before her arrival. She also stated that the coroner told her
that the deceased’s legs was found lying underneath the platform hole with his
legs wrapped around the ladder and his head close to the drain. Coroner Lysek testified that he did not tell
CO Weisenberger on December 22, 2010 where the decedent fell from because he
could not identify that location. CO
Burgei testified that the coroner did not describe the deceased’s orientation,
but the coroner did indicate that his body was found about three and a half to
four feet away from underneath the 17’ foot platform opening in the floor area
between the drain and the ladder that led to the 17-foot platform. (Tr. 284-86, 334, 371, 373, 504, 832-33, 1687;
JX-II, at p. 2, JX-XIV, D, at p. 10).
The Court finds that CO Weisenberger was mistaken when she testified
that the deceased was found lying on the floor below the catwalk surrounding
the “east” combustion chamber. The
deceased was found lying below the catwalk surrounding the west combustion
chamber. (Tr. 317, 496, 505-06; RX-RR,
RX-MM).
[83] A
note made by CO Weisenberger on December 22, 2010 states:
Zach lysic [sic] Cornor [sic]
Thinks hit head on sharp object.
She added during her testimony that the coroner told
her that the deceased hit his head on a sharp object on the way down, and that
the coroner never identified any object that the deceased might have hit his
head on. By letter dated November 14,
2011, Coroner Lysek informed CO Weisenberger that the deceased’s “cause of
death was determined to be Blunt Force Head Trauma, and the manner of death was
Accidental.” (Tr. 329-30, 332-33, 1107-11, 1688-89; JX-XIV,
at p. 12, RX-C).
[84]
He testified that the assertion was not supported by facts and was “an
assumption based on the remarks of the coroner and personal opinion.” He admitted that he based the guesstimates and
assumptions contained in his December 22, 2010 email to CO Weisenberger upon
what he heard from the coroner earlier that day that were not in final form. (Tr. 896, 909-10, 927; RX-D). AD Kulp testified that CO Burgei’s assertion
in his email that the deceased fell 17-feet through an open hole in the catwalk
was later found to be inconclusive because OSHA did not know if the deceased
fell from the 17-foot catwalk. (Tr.
1168).
[85]
CO Burgei testified that it appeared to him that the tapes had been connected
because there was partial tape tied to the left side and partial tape tied to
the right side. He also testified that
he could not determine who cut or ripped the yellow tape, or when it was put
up, ripped or cut. (Tr. 906; RX-D).
[86]
CO Burgei testified:
Q
… You don’t have any facts when you drafted this [December 22, 2010 email to CO
Weisenberger] that he was up on the catwalk.
Do you?
A. No.
Q
‘The direction that he fell was undetermined.’
You have no information to determine whether or not he fell. Do you?
A. No.
(Tr. 908; RX-D).
[87]
CO Weisenberger testified that Mr. Narkin told her that Siemens had created the
openings on the platform while performing the overhaul of the combustion
chambers in CT-6. She also testified
that Siemens’ District Manager Rich Gautille
told her that Siemens had previously removed all of the walkways (also referred
to sometimes as platforms or catwalks) around the combustion chambers. She testified that Siemens was responsible
for reconstructing the walkways, creating the openings in the platform on
December 21, 2010, and not covering the openings by the end of its night shift
[3:30 a.m.] during the morning of December 22, 2010. She also stated that Siemens’ safety
representative, Daniel Cunnard, indicated to her that the deceased may have fallen
off the ladder, or a 10 foot high platform that was adjacent to the 17-foot
high platform. (Tr. 174-75, 242-47, 252-57,
263-64, 335, 338, 343-44, 360, 378, 416, 842, 1295-96; JX-XIV, at pp. 10, 13, JX-XV,
at p. 6, GX-7, RX-J; SF-11, SF-12).
[88]
Neither CO Weisenberger nor CO Burgei took any video at the accident site on
December 22, 2010. (Tr. 277, 421).
[89]
The tarps were used to protect the combustion chambers when the roof was
removed from CT-6. (Tr. 337-38; JX- XIV,
at p. 11). A photograph taken by
Detective Lalatola also shows a tarp hanging down near, but not going across,
one of the 17-foot platform openings.
(JX-XXXIII, at p. 13).
[90]
In about early 2011, Mr. Cunnard told CO Weisenberger that caution tape was
used as a physical barrier for the crane as a fall protection warning in CT-6. (JX-XV, at p.3). Another Siemens employee told CO Weisenberger
on March 4, 2011 that the Siemens’ December 21, 2010 night shift crew worked on
the ground within CT-6. (JX-V, at p.
2). At about the same time, a Siemens’
employee told CO Weisenberger that Siemens’ “didn’t complete catwalk – 2
openings on each chamber” on December 21, 2010 and that the later December 21,
2010 night shift crew performed bottom [ground floor] work and did not work on
the catwalks. (Tr. 1287; JX –XV, at p.
8).
[91] CO
Weisenberger testified that CO Burgei did not wear any fall protection when he
went up the ladder onto the platform because Mr. Fisher assured him that he
would be safe up there and Mr. Fisher would keep him away from the hole while
acting as the hole’s attendant. (Tr.
163-64, 310, 777, 843-45).
[92]
CO Weisenberger testified that neither she nor CO Burgei took any measurements
of anything at the accident scene on December 22, 2010. She was present when the coroner measured the
distance from the floor to the platform at 17-feet, one and 31/32s of an
inch. She made a simple sketch of the
accident site that showed two small circles connected with two horizontal lines
that were crossed by an oblong shape with “Turbine” written on it. She further testified that she did not know
the deceased’s height or weight or whether he could fit through the platform
opening. CO Burgei also testified that
he did not take any measurements to determine whether or not the deceased could
fit through the opening. OSHA never
asked Calpine to provide it with the opening’s measurements. (Tr. 277, 283, 288, 298-99, 330-31, 387, 777,
849, 853-54, 1177, 1652; JX-XIV, at p. 9, JX-XVI, at CALPINE000089).
[93]
AD Kulp testified that OSHA did not find any blood or tissue evidence related
to the deceased along any fall path from the 17-foot high platform to the
floor. (Tr. 1145-46). In her responses to Respondent’s First Set of
Requests for Admissions, Complainant denied that she did not know with a
reasonable degree of certainty from where the deceased fell. (Tr. 1158-59; JX-XI, at p. 5). At the trial, AD Kulp testified that it was
“inconclusive that he actually fell from that location [the walkway surrounding
the BK-2, west combustion chamber at CT-6].
(Tr. 1159, 1170-72).
[94] At
one point in her testimony, AD Kulp agreed that OSHA had asserted that the
deceased fell to his death through an opening left by Siemens in an overhead
walkway. Later on, she testified that
she did not know that OSHA has contended that the deceased fell to his death
through the opening left by Siemens in the overhead walkway. (Tr. 1144-45, 1151-52).
[95]
CO Weisenberger testified that she was not sure if the forty percent referred
to a day’s work performed on December 21-22, 2010, or from the beginning to the
end of the project. (Tr. 379).
[96]
Although he never measured the opening, Mr. Killgore estimated the platform
opening’s dimensions at “a foot and a half, or maybe two foot by maybe a foot
in the inside, pie shaped.” He testified
that he thought fall protection was needed going up to the platform, but not in
the platform area where there were handrails.
(Tr. 1429-30; JX-XXXIII, at p. 3).
[97]
Mr. Killgore estimated that the leaning grate was probably two and a half to
three feet at the upper, largest part, and maybe three feet high and a foot and
a half to two feet at the bottom. (Tr.
1430).
[98]
The Court finds that CO Burgei took photographs of the opening to the left of
the gate on the upper platform before Mr. Killgore installed the grate at the
opening. (Tr. 778-79; GX-1, at pp. 8,
11, 12).
[99]
AD Kulp testified that she was responsible for directing and managing
enforcement, community program and office administrative activities. (Tr.
1038). CO Weisenberger testified that
the OSHA 1-B Worksheet in the file indicated that the decedent was the only
employee listed as being exposed to the floor opening for an estimated five
minutes because he was given a written work order to go into the area to
perform the task, and fell 17-feet to his death. The Worksheet further identified Respondent as
the “controlling and exposing employer.” She testified that the coroner told her that
the deceased fell 17-feet to his death. (Tr. 350-51; JX-III). The Court credits the testimony by the coroner
that he did not tell CO Weisenberger on December 22, 2010 where the decedent
fell from.
[100]
AD Kulp testified:
Q. Is there any evidence to this day that [the
deceased] was even up on the [upper] walkway of BK2 unit six?
A. No, and that’s why it’s inconclusive.
(Tr. 1172).
[101]
AD Kulp further testified: “We assumed and knew from the facts that he was
given an assignment to go into that area.
Whether he was there to assess or actually perform the work, because we
didn't witness how he needed to do that, to make an assessment, whether that
would require you to go up to the top we don’t know, but we did obviously have
a fatality as a result.” (Tr. 1305-06). She also testified that she had learned that
the deceased had reportedly been awake for at least 24 hours before the
accident. (Tr. 1125).
[102]
Coroner Lysek testified that the statement was based upon Deputy Coroner
Smith’s observation and wording and that only he [Coroner Lysek] climbed to the
top of the 17-foot platform. He further
testified that the reference was “misleading” because “when you’re standing on
the bottom looking up it’s a total different appearance then when you’re
standing on the top catwalk looking down…. The body wasn’t directly under
it. It’s just a generalization in what
he’s [Deputy Coroner Smith] saying that the body was beneath it. Well, the catwalk is above it so it is
beneath it. It doesn’t mean it’s
directly under it, because the ladder, which is ladder “B”, the tall access
ladder to up to the 17-foot catwalk, is not under it, it’s away from it, as is
ladder “D” where [the decedent’s] head is.
So it’s the terminology and the phrasing I think is not accurately [sic]
– if you’re reading that I think it could be misleading – you –[.]” (Tr. 1724-25, 1732-33).
[103]
This clarification was provided during Respondent’s redirect examination of the
witness. (Tr. 1730-33).
[104]
Coroner Lysek testified that the blood spatters near the body show that the
decedent did not move after his impact with the floor. (Tr. 1645, 1655-1657; JX-XVI, at
CALPINE000099-100). Coroner Lysek has
attended courses in blood pattern analysis and has been through basic and
advanced level courses at the Blood Institute in Coming, New York. (Tr. 1586).
[105]
There was a “turbine deck” (also referred to
as “the IGV platform”) with a five or six-foot ladder next to the
combustion chamber with a 17-foot platform.
(Tr. 343; JX-XV, at p. 4, RX-RR at “K”). Mr. Lutz testified that this five or six-foot
ladder was used to get to the IGVs in order to make adjustments. Mr.
Varga testified that he went on the IGV platform to perform maintenance and
lubrication on the IGVs. (Tr. 507-08,
551, 744; RX-MM, at letter “G”). Mr.
Lutz testified that he guessed that someone could get up to the combustion
chambers from the IGV platform “if you wanted to monkey it up a little
bit.” There is no ladder from the IGV
platform to the combustion chambers.
(Tr. 551; RX-MM).
[106]
He is a board certified forensic and anatomic clinical pathologist. He has a bachelor’s of science degree in
Biology, with a minor in chemistry from Rider College. He attended medical school at the University
of Medicine and Dentistry, Robert Hood Johnson Medical School, and performed
clinical years at Cooper Hospital.
Thereafter, he completed his anatomic and clinical residency at the
University of Pennsylvania, and a one-year fellowship at the medical examiner’s
office. He then finished his residency
at Drexel University, College of Medicine.
After that he completed fellowship training in forensic pathology at the
Philadelphia’s medical examiner’s office. He testified that he has performed
about 2,500 autopsies. (Tr. 1670,
1739-41). Chief Deputy Coroner Smith also
attended the autopsy. (RX-L, at p. 13).
[107]
Dr. Chmara testified as follows regarding his job:
Q. Right.
But your job, when you were asked to do this autopsy was simple to determine
the cause of death and the manner of death?
A. And to convey how the injury occurred, sure.
Q. Right.
Your job was not to determine where the decedent fell from?
A. Part of how the injury occurred it would fall
under the realm, I would think. That’s
my job, to tell somebody in a courtroom what happened. So --.
(Tr. 1773).
[108]
The autopsy report stated that “[T]he decedent had been walking on a cat walk
where reportedly there was [sic] missing grates on the floor. He reportedly fell through one of these areas
where the grate was missing. He is found
below after workers had not seen him for some time. Approximate height of the fall is 17-feet.” He testified that this part of the
Circumstances section of the Autopsy Report is “not at all” factual based upon
what he knew at the time of his testimony.
(Tr. 1746-47; RX-L, at p. 9).
[109]
CO Weisenberger testified that the coroner told her that the deceased suffered
broken ribs, a broken neck, and a head laceration, and that he died from a
fall. (Tr. 363). The Final Pathologic Diagnoses in the Autopsy
Report identified multiple blunt force injuries including neck fracture, skull
fractures right frontal, and right rib fractures. Dr. Chmara testified that there was a large
abrasion on the top of the decedent’s head, which he described as the point of
impact where the decedent came in contact with the ground. He further testified that the skull fracture
was “one of the injuries that probably would have rendered him incapacitated at
that moment, the concussive effect from a fall and blow like that is
significant.” (Tr. 1749-50; RX-L, at p.
7).
[110]
Coroner Lysek testified that he “went back out to the scene to look at the
scene again to determine if I could come to a conclusion as to where [the
decedent] fell from.” (Tr. 1695-96).
[111]
Dr. Chmara testified that he had been to hundreds of scenes where the body was
pressed back with the crotch that close to the ladder. (Tr. 1770).
[112]
Dr. Chmara testified that forensic pathology evolves and that he’ll receive
information today on a case that he did five years ago and may come up to
another determination. (Tr. 1773).
[113]
CO Weisenberger found that Calpine trained all of its maintenance employees on
both general industry and construction fall protection methods. She further found that Calpine’s training
went “into substantial detail regarding the methods and means of fall
protection across both vertical and horizontal unguarded edges.” (Tr. 368-69,
408-09, 1504-05; JX-III, at p. 2),
[114]
The purpose of Calpine’s policy on “Barricading Requirements”, SPM-39, is to
educate employees [it also applied to contractors performing work at BEC]
regarding safe work practices when working on or around areas or equipment
where barricades, warning tape or signs are being utilized. SPM-39 defined “Barricade”
as “a rigid device used to warn individuals of a danger and prevent them from
exposure to the danger.” It defined
“Warning Tape” as a “semi-rigid device that may be utilized to “rope-off” an
area or piece of equipment that poses a danger to individuals.” It defined “Signs/Placards” as devices “that
give written/visual indication of hazards or directions (i.e. “Do Not Enter,”
“Overhead Work,” etc.)[.] ” SPM-39
stated that Yellow Tape “denoted a possible hazard to personal health and
safety. Areas roped off by yellow
(Caution) tape may be entered, but the use of caution and heightened awareness
should be exercised.” (Tr. 404; RX-J, RX-PP).
[115]
Mr. Narkin testified that there were between 25 to 35 required safety training
modules covering topics that included fall protection, ladders and staircases,
walkways and walk surfaces, and scaffold safety. (Tr. 1450-53, 1455,1458-59; RX-II (admitted
portion only), RX-JJ (admitted portion only)).
[116]
Mr. Miller testified that during the Fall, 2010, he observed a Siemen’s
millwright standing on the top railing of one of the lower platforms along a
combustion chamber reaching up to tighten a fastener. He told the Siemen’s worker to get down from
the railing, or get his harness on and tie off to do that job. (Tr. 1554-55, 1559).
[117]
Mr. Varga testified that he agreed that he was required to receive training in
these topics at Calpine. (Tr. 716-22).
[118]
Respondent’s Fall Protection policy stated (in part):
4.0 Responsibilities
…
4.3 Supervisors
…
4.3.2 Perform a fall hazard assessment for each job
and determine the proper equipment and
procedure for that specific task.
…
4.4 Employees – are responsible to ensure
that they are trained and maintain compliance with this procedure.
5.0
Hazard Identification
The Supervisor will evaluate
each situation or work procedure when employees may be exposed to a fall of 4
feet or more. The supervisor will be
responsible for developing a plan to eliminate the exposures, if possible, or
to select the appropriate fall protection systems and/or equipment.
…
7.0 Fall Prevention/Protection Required
The following are examples of
situations where fall prevention/protection would be needed. There are other situations where a fall of 4
feet or more (6 feet for construction related activities) could be possible.
…
7.2 Holes- Personal fall arrest systems,
covers, or guardrail systems shall be erected around holes (including sky
lights) that are more than 4 feet above lower levels.
...
8.1.11 At holes, guardrail systems
must be set up on all unprotected sides or edges. When holes are used for the passage of
materials, the hole shall have not more than two sides with removable guardrail
sections. When the hole is not in use, it must be covered or provided with guardrails
along all unprotected sides or edges.
(Tr. 599-600; RX-PP).
[119] Mr. Varga testified that he learned through
training and experience to assess the work area before performing a task. Mr. McClelland testified that he is required
to participate in safety training every month.
(Tr. 742, 1796).
[120]
Mr. Narkin testified that the JSA or JSB called for each worker to write down,
at or near the task site, each task that he is doing and each hazard that he
might encounter, as well as how he intends to overcome any identified hazard. The JSB usually remains with the worker until
the end of the day, when it is then submitted to Mr. Fischer. He testified that he did not think that a
JSA/JSB form was ever found that related to completing the December 21, 2010 task
to install a new spark rod in CT-6. (Tr.
1518-23, 1529; JX-XIII).
[121]
Mr. Lewis testified that “[the decedent] was very meticulous about his safety,"
“always made sure he had the proper PPE [personal protection equipment],” and “always
followed the rules. He didn't do it
begrudgingly. He just did it. So that tells me he followed it, he believed
in it.” (Tr. 601-02). Mr. Lutz testified that the decedent “took
care of things when it came to safety” and “tried to follow the rules the best
he could, I never really seen him ever do anything that was other than what was
expected of him.” (Tr. 483).
[122]
Coroner Lysek estimated that the
decedent had been up without sleep for about 20 hours before the accident. (Tr. 1679-80; RX-L, at p. 5). The decedent was 49 years of age. (RX-L. at p. 7).
[123]
The citation was amended as follows:
Citation 1, Item 1a Type of Violation Serious
29 CFR 1910.23(a)(7):
Temporary floor opening(s) were not guarded by standard railings or
constantly attended by someone:
(a) CT6, adjacent to the ladder access way – On or
about December 22, 2010, a temporary floor opening in the steel grated
platform, which surrounded the turbine chamber, was not guarded by standard
railings or constantly attended to prevent employees from falling a distance of
no less than 16 feet through the unguarded opening.
(Complaint, p. 3).
[124]
The COs did not interview the first responders who arrived at the accident site
before the COs, including Deputy Coroner Suzanne Dannenhower, Deputy Coroner
Coy Smith, Bethlehem Police Officer Christopher Kopp, Detective Sergeant
Alleshouse, Detective Iatorola, Officer J. Hoffman, and Officer Phelps. CO Burgei testified that it was important,
and he was trained, to interview first responders as soon as possible. (Tr. 326, 338-39, 793-99, 1590; RX-M). .
[125]
A floor opening is defined in 29 C.F.R. § 1910.21(a)(2) as: “An opening
measuring 12 inches or more in its least dimension, in any floor, platform,
pavement, or yard through which persons may fall; such as a hatchway, stair or
ladder opening, pit, or large manhole.
Floor openings occupied by elevators, dumb waiters, conveyors, machinery,
or containers are excluded from this subpart.”
[126]
The Court finds that Siemens created the floor opening in the upper catwalk on
the north side of the west combustion chamber prior to the accident.
[127]
See Atl. Battery Co., 16 BNA OSHC 2131, 2166 n.56 (No. 90-1747, 1994) (multi-employer
worksite defense rejected when employer had “control” over the cited
conditions).
[128]
Mr. Killgore testified that he could provide information about the progress of
Siemens’ work if someone from the BEC plant operations staff needed to
know. (Tr. 1419-20).
[129]
There is a conflict in the
testimony as to whether Mr. Narkin was in the room when Mr. Lewis stated he had
not changed the spark rod due to the hazard presented by the floor
openings. Messrs. Lewis and Lutz thought
he was present at the time, but were not completely sure. Mr. Narkin was sure he was not told about the
floor openings. On this discrepancy, the
Court credits the testimony of Messrs. Lewis and Lutz over that of Mr. Narkin. Mr. Narkin testified that he likes to attend
the morning shift turnover meetings to insure “that the turnover is getting
done formally and with care. … So I like being there to make sure it’s being
done in the control room in a controlled manner and that people are taking
their time with it.” He further
testified that by attending the turnover meetings, “It also gives me a chance
to get information firsthand from the shift that’s leaving, while they’re
giving it to the guy that’s relieving them I can get information that way too.”
Mr. Narkin's purpose for attending the
morning shift turnover meetings was to be attentive and gather information from
the outgoing crew. The Court found his
denial of Mr. Lewis’ report of a hazard to be a convenient explanation for his
inaction in not removing the spark plug replacement task from the night order
or warning the deceased of safety concerns with regard to the 17-foot platform
a day before the accident. The Court
also observed the demeanor of Messrs. Lewis, Lutz and Narkin when testifying
and found Mr. Narkin’s demeanor to be defensive and unpersuasive as to this discrepancy. Some of his testimony was fast and not
deliberative; evasive and not to the point. By contrast, he testified that he could
“[a]bsolutely not” recall any conversations with either Messrs. or Lewis about
the unsafe condition at CT-6’s 17-foot platform, and sure that he “didn’t know
the condition.” Mr. Narkin was also
impeached when he inaccurately testified at trial that he did not know in
December 2010 that the catwalks in CT-6 had to be at least partially removed
from the combustion chambers. At his
deposition, he answered a similar question affirmatively and without
equivocation. As knowledge can be
imputed through others, resolving this testimonial conflict is somewhat
redundant. (Tr. 1002-03, 1471-73, 1488-92).
[130]
Mr. Killgore testified:
Q. Describe for us what activity took place on
that shift.
A. All the activities?
Q. As it relates to the platforms.
A. They hot
bolted them, which means they basically just kind of tightened them up snug,
but didn’t torque them properly. Both the platforms and the catwalks. And they set the big roof….
(Tr. 1395-96).
[131]
The Court find that for the purposes of imputed knowledge of the hazard
condition, TMG, including its representatives Messrs. Killgore and Rice, are
regarded as a single entity with Calpine.
Messrs. Killgore and Rice were the eyes and ears of Calpine for the
overhaul project at the BEC facility. At
his deposition, Mr. Rice stated that he worked for Calpine because TMG was a
division of Calpine Corporation. Messrs.
Killgore and Rice coordinated the tasks that Calpine employees performed within
CT-6 on a regular basis. Mr. Miller testified that Mr. Killgore signed as a
representative of Calpine on a plant visitor and contractor sign-in sheet. Both TMG and Calpine BEC received the daily
turnover reports prepared by Mr. Killgore.
TMG and Calpine shared a common worksite, had interrelated operations,
and shared supervision on site within CT-6.
See Loretto-Oswego Residential
Health Care Facility, 23 BNA OSHC 1357, 1358 (No. 02-1164, 2011)
(consolidated) petition denied, 692
F.3d 651 (2d Cir. 2012); C.T. Taylor Co.,
20 BNA OSHC 1083, 1086-87 (No. 94-3241, 2003) (consolidated) (purposes of Act
best effectuated by two entities being treated as one.); Kulfa Constr. Mgmt. Corp., 15 BNA OSHC 1870, 1872-73 (No. 88-1167,
1992) (finding construction standards applicable to entity that was the “eyes
and ears” of the building owner for on-site safety matters even when the
building owner maintained overall safety responsibility.). See
also Nantahala Power and Light Co. v. Thornburg, 476 U.S. 953, 957-58
(1986) (finding it appropriate to ignore corporate form and treat separate
entities as one to avoid frustration of a statute’s purpose).
[132]
AD Kulp testified that the citation to Calpine was based upon a “potential
exposure.” (Tr. 1233).
[133]
The conclusion reached by both Coroner Lysek and Forensic Pathologist Chmara
that the decedent did not fall through the upper platform opening is
corroborated by the fact that the decedent was found on the floor with gloves
on his hands and he had a routine of wearing gloves while climbing ladders, and
removing them after reaching the top of a ladder. (JX-XI, at p. 4 – Complainant’s Responses to
Respondent’s First Set of Requests for Admissions, No. 11).
[134] The evidence supports the
Court’s finding that a task listed on a Calpine night order was not to be
performed if plant conditions did not allow the task to be performed safely. (Tr. 649-50, 1463-71; RX-DD).
[135] The Court finds that it was not reasonably
predictable that the decedent would ignore the obvious condition of the missing
grate in the upper platform which was visible from the ground to virtually all
others who viewed the combustion unit, disregard the fact that the tarps were
completely covering the areas where the igniter tip would be installed even
though the tarp was clearly visible from the ground, and disregard Calpine
safety requirements after viewing the hazard and fail to go back and get his
fall protection assigned to him by Calpine, or pass on performing the task as
Mr. Lewis had done the day before.
[136]
The Court finds that employees standing on the ground floor in the area north
of the west combustion chamber were not exposed to the upper platform opening
hazard that was more than 17-feet above them.
[137] The Court notes that Respondent was
not cited for exposing Messrs. Lewis or McClelland to any upper platform
opening hazards when they entered CT-6 a day, or so, before the accident to
perform tasks therein. Also, eleven
Siemens employees worked in the southern part of CT-6 during the night shift
that ended at 3:30 a.m., December 21, 2010, and Siemens was not cited for
exposing any employee to opening hazards on the upper platform. Similarly, Siemens employees worked on the
ground floor of CT-6 during the night shift that ended at 3:30 a.m., December
22, 2010; just an hour or so before the accident and Siemens was not cited for
exposing any employee to opening hazards on the upper platform.
[138]
See Special Metals Corp., 9 BNA OSHC 1132, 1134 (No. 76-4940, 1980) (finding
climbing a 30 foot ladder to an unguarded platform is beyond normal employee
random movement contemplated by the access test leading to the conclusion that
the unguarded grating was too remote to pose a threat to the safety of
employees); Zwicker Elec. Co., 5 BNA
OSHC 1329, 1332 (No. 11771, 1977) (Commissioner Barnako concurring) (finding no
violation where employees not within 30 feet of floor opening); Garden Ridge, Store # 46, No. 10-1082,
2010 WL 5600075 (O.S.H.R.C. A.L.J. November 19, 2010) (Secretary failed to
prove that employee(s) were within 10 feet zone of danger of an hydraulic ram);
EMCO Mech. Contractors, No. 89-0773,
1989 WL 223452 (O.S.H.R.C. A.L.J. October 20, 1989) (showing exposure where
Secretary proved employees had access to a zone of danger that was within 10
feet of an escalator opening in the course of their duties); Shank-Ohbayashi,
No. 88-0497, 1989 WL 223342 (O.S.H.R.C. A.L.J. March 31, 1989) (upholding citation
where there was ample evidence that employees going about assigned duties would
pass within 10 feet of an insufficiently unguarded “skip pit”); Rudolph & Sletten, Inc., No.
87-1983, 1988 WL 212672 (O.S.H.R.C.
A.L.J. November 21, 1988) (finding no
access where employee’s assigned duties make it unlikely that employee would
have occasion to pass near the floor opening); Merritt-Meridian Constr. Corp., No. 84-760, 1985 WL 44736, at *3 (O.S.H.R.C. A.L.J. September 13, 1985) (finding that violation was
unproven where no evidence that employees were ever closer than 10 or 15 feet
from the zone of danger – “too remote”).
[139]
The Court finds that the initial conclusions reached by Officer Kopp and CO
Burgei on December 22, 2010 that the decedent fell through the floor opening in
the upper platform to have been premature and superficial. What was quickly presumed to be an obvious
conclusion, turned out to be an error when all of the facts were carefully
developed and considered.
[140]
The Court finds since the violation concerns a floor opening hazard that it is
appropriate to measure from the floor level of the 17-foot upper platform to
the decedent’s feet at the time of his fall, and that distance exceeds ten
feet.
[141]
Testimony from two employees,
Messrs. McClelland and Lewis, established that each of them did, in fact, make an
assessment of the safety issues related to an assigned task. Mr. McClelland utilized personal fall arrest
equipment to work in the area where the upper platform floor was
incomplete. Mr. Lewis, when assigned the
same task as the decedent, chose not to perform this task after observing the
holes in the upper catwalk platform the previous day. (Tr. 578-81; 1799-1804).
[142]
These job conditions including making an assessment as to whether or not the
task could be performed safely and whether or not the two expressed conditions
relating to the igniter replacement task had been met; i.e. that “[i]f tarps and Siemens are not in the way.”
[143]
AD Kulp testified that OSHA knew as a result of its investigation that the
decedent did not have his tool belt when found and may have entered CT-6 to
assess the job conditions. (Tr. 1294,
1303-05).
[144]
In Kerns Bros., the Commission found
the Secretary had not presented evidence to rebut the employer’s evidence that its
employees took the work rule seriously and that it had a “formal,
well-conceived program . . . and exercised reasonable diligence in in carrying
out that program.” Kerns Bros., 18 BNA OSHC at 2071.
[145]
Tr. 836, 1145.
[146]
The Secretary offered no evidence or argument that employees other than the
decedent could have been exposed to the zone of danger during the December 21
night shift when the same floor openings existed on the upper platform as
existed at the time of the accident.
(Tr. 127).
[147] The Secretary makes no argument that a Calpine
employee would come in contact with the zone of danger by inadvertence. The undisputed evidence shows that the
opening in the upper platform was clearly visible from the ground. Testimony from Messrs. Lewis and McClelland
affirms that, in actual practice, it was unlikely that Calpine employees would
inadvertently expose themselves to the zone of danger and get within ten feet
of the upper platform opening. Calpine
employees, including the decedent, were aware that Siemens was performing work
on the combustion chambers and it was unlikely that a Calpine employee would
inadvertently expose himself to a condition on the upper platform which was
obvious from the floor. The decedent’s
safety history and past practices support that he would not inadvertently
expose himself to the zone of danger, which was clearly visible from the
ground. The Court finds that it was
reasonably predictable that the decedent would go into CT-6 to assess the
safety of the job site prior to performing any work, and he would either decide
not to do the work as Mr. Lewis had done, or leave and return with all needed
safety equipment and tools as Mr. McClelland had done. The Court finds that the Secretary’s theory that the
decedent would have exposed himself to the zone of danger based on the December
21, 2010 Night Order is a speculative hypothetical which fails to meet her
burden of proof with regard to showing employee exposure to the hazard.
[148]
Because the Secretary failed to prove her prima facie case, the Court has not
addressed Calpine’s asserted defense of
unpreventable employee misconduct. To
establish this defense, the Respondent must prove that it: (a) established work rules designed to prevent
the violation, (b) adequately communicated those rules to its employees, (c)
took steps to discover violations, and (d) effectively enforced the rules when
violations were discovered. Capform, Inc., 19 BNA OSHC 1374, 1377
(No. 99-0322, 2001) (citation omitted).
(Tr. 430-31; JX-III, at p. 2).